AC output: 240Vac ~ 50Hz
Rated power: 2000W +/- 5%
Peak power: 2200W +/- 5%
Phase: Single
Displacement: 135cc
Motor: 4 stroke
No load speed: 3500 RPM +/- 10%
Fuel tank capacity: 7L
Fuel type: Unleaded
Oil tank capacity: 550ml +/- 10%
Oil type: 4 Stroke (SAE 10W-30)
Net weight: 19kg
Product Dimensions: 44.5cm x 36.5cm x 37cm (L x W x H) +/- 10%
This product complies with: Safety:
AS/NZS 3010: 2017
AS/NZS 3100: 2017
For other issues not covered in this chart, please call Customer Service on 1800 909 909.
Troubleshooting Specications
Trouble Possible cause Suggested remedy
No electrical output
1. Faulty receptacle 1. Have service centre replace receptacle
2. Overload has been triggered
(red Overload light on).
2. Remove all appliances. Stop the
generator, and restart. Reconnect
appliances but with reduced load.
3. Faulty power cord 3. Have an electrician replace cord.
4. 240Va.c Outlet Power On/Off switch (1)
turned off.
4. Check the 240Va.c Outlet Power On/
Off switch (1) is “ON”.
Repeated overload
1. Overload 1. Reduce load
2. Faulty cords or equipment 2. Check for damaged, bare, or frayed
wires on equipment. Replace.
Generator overheating
1. Generator overloaded 1. Reduce load
2. Insufficient ventilation 2. Move to adequate supply of fresh air
3. Octane rating of fuel too high 3. Drain fuel and use 91 octane rated
unleaded fuel
Generator keeps stopping,
or is operating rough
1. Check oil level 1. Add oil so oil is at the correct level.
Refer page 21-22 of this manual.
2. Generator not sitting on flat
and level surface
2. Move generator to a level and
flat surface
3. Motor needs to be cleaned of carbon 3. Remove, check and clean spark
arrestor if needed.
Remove, clean or replace spark plug (20)
Specifications
Accessories and After Sales
Should you nd any of the following accessories are worn or past their user