Do you have a question about the Alfa Laval TE67 Series and is the answer not in the manual?
Information on proper usage, safety notes, and compliance with regulations.
Instructions designated for qualified technical personnel.
Disclaimer regarding non-observance, misuse, or modification.
Application for overpressure/vacuum measurement and media compatibility checks.
Verification of delivered parts for damage and consistency.
Device identification via manufacturing label and ordering code.
Critical warnings and safety precautions for device installation.
Procedures for careful handling and installation of the device.
User responsibility to check installation and defects before operation.
Safely disassembling the device under pressure-less conditions with precautions.
Guidance on cleaning the device housing with a damp cloth.
Contacting local office and email for return requests, including Return Number.
Standard warranty period, exclusions for misuse, modifications, or damage.
This document describes the Alfa Laval Pressure Gauge TE67Dxxxxxxxx, a precision measuring device designed for applications in overpressure and vacuum measurement.
The Alfa Laval Pressure Gauge TE67Dxxxxxxxx is used to measure pressure in various applications. It is designed to provide accurate readings for both overpressure and vacuum conditions. The device's manufacturing label provides essential data for identification, including type, item number, and serial number. This label is crucial for product identification and must not be removed.
The pressure gauges are available in different configurations, primarily distinguished by their dial size and clamp connection type.
Dial Sizes and Connections:
General Specifications:
Measuring Ranges (bar/kPa or bar/psi): The device is available with various measuring ranges to suit different application requirements:
Wetted Part Material:
Surface Finish Wetted Parts:
Scale Options:
Certificates: Various certification options are available, including Calibration Certificate, 3.1 Certificate, 3A, and combinations thereof.
Intended Use: The Alfa Laval Pressure Gauges TE67Dxxxxxxxx are specifically developed for applications involving overpressure and vacuum measurement. Users are responsible for verifying the device's suitability for their intended application. If any doubts arise, contacting Alfa Laval is recommended to ensure proper usage. The device is designed for use with permissible gases or liquids as specified in the data sheet, and compatibility with media wetted parts must be ensured. All technical data listed in the current data sheet are binding and must be adhered to.
Installation: Installation must only be performed by qualified technical personnel who have read and understood the instruction manual. The device should only be installed when the system is depressurized. It is a high-sensitive precision measuring device and must be handled with care, both in packed and unpacked conditions. No modifications or changes should be made to the device. Packaging and protective caps should be removed directly before assembly, and the protective cap should be stored and placed back on the pressure post immediately after disassembling. Force should not be used during installation to prevent damage to the device and the plant.
Initial Start-up: Before start-up, users must check for proper installation and any visible defects. The device can only be started and operated by authorized personnel who have read and understood the instruction manual. It must be used strictly within its technical specifications as outlined in the data sheet.
Placing Out of Service: Disassembly of the device should only occur under pressure-less conditions. Depending on the medium, it may pose a danger to the user, so adequate precautions for purification must be observed.
General Maintenance: In principle, the Alfa Laval Pressure Gauge TE67Dxxxxxxxx is maintenance-free. If desired, the housing of the device can be cleaned using a damp cloth and non-aggressive cleaning solutions.
Service and Repair: For any return of the device, whether for recalibration, decalcification, modifications, or repair, it is necessary to contact the local Alfa Laval office to ensure prompt service. Users should send an email to Alteq.PartsandService@alfalaval.com, including the number of devices being sent, and request a Return Number. After cleaning the device, it should be packed shatterproof and sent to Alfa Laval Kolding A/S, indicating the provided Return Number.
Warranty Conditions: The warranty period is 12 months from the date of delivery, subject to legal warranty conditions. Warranty claims will not be accepted for improper use, modifications, or damages to the device. Damaged diaphragms are also excluded from warranty. Defects resulting from normal wear are not covered by warranty services.
| Brand | Alfa Laval |
|---|---|
| Model | TE67 Series |
| Category | Measuring Instruments |
| Language | English |