PELLET STOVE
„LUCA 12
INSTRUCTIONS FOR USE AND MAINTENANCE OF LUCA 12
ENG_v.1.0

Table of Contents

Questions and Answers

  • D
    Debra RamirezAug 19, 2025
    What does Er05 error mean on Alfa Plam LUCA 12 Pellet stove?
    • J
      Jennifer BrownAug 19, 2025
      The Er05 error on your Alfa Plam Pellet stove indicates that the temperature of flue gases exceeds the limit, or there is insufficient heat transfer, obstruction of flue gas drain, or a faulty flue gas probe. To address this, wait for the furnace to shut down and then press P2 for more than 3 seconds.
  • J
    Joshua CameronAug 21, 2025
    What does Er03 error mean on Alfa Plam LUCA 12?
    • S
      stacycantuAug 21, 2025
      The Er03 error on your Alfa Plam Pellet stove can be caused by poor combustion (too few or too many pellets remain in the combustion chamber), an empty pellet tank, or a faulty flue gas probe. Also, check the size of the pellet granules and for contamination of the furnace chamber. To address this, wait for the furnace to shut down and then press P2 for more than 3 seconds.
  • M
    Melissa CarneyAug 23, 2025
    What does Er01 error mean on Alfa Plam LUCA 12 Pellet stove?
    • K
      Kaylee RodriguezAug 23, 2025
      The Er01 error on your Alfa Plam Pellet stove indicates a high temperature inside the furnace or too high a temperature in the room where the furnace is assembled, or a faulty thermostat. Wait until the furnace has cooled and then unscrew the plastic cap on the thermostat and press the reset button.
  • T
    Timothy WilliamsAug 26, 2025
    What does Er02 error mean on Alfa Plam LUCA 12 Pellet stove?
    • M
      Michelle WolfAug 26, 2025
      The Er02 error on your Alfa Plam Pellet stove is caused by an obstruction of flue gas drain, incorrect funnel installation, or a faulty pressure switch. To address this, press and the P2 key for more than 3 seconds.
  • N
    Nathaniel BoydAug 28, 2025
    What does Er17 error mean on Alfa Plam LUCA 12 Pellet stove?
    • B
      Brittany HernandezAug 28, 2025
      The Er17 error on your Alfa Plam Pellet stove means the primary air flux meter does not adjust the operation of the furnace. Turn the furnace off to reactivate the air flux meter. Wait for the furnace to shut down and then press P2 for more than 3 seconds. Also, check pipe contamination for primary air inlet.
  • T
    Todd SmithAug 30, 2025
    What does Er08 error mean on Alfa Plam LUCA 12 Pellet stove?
    • M
      Michelle McneilAug 30, 2025
      The Er08 error on your Alfa Plam Pellet stove indicates that the flue gas engine is not responding or the flue gas engine operates at a speed that is different from the set speed. To address this, wait for the furnace to shut down and then press P2 for more than 3 seconds.
  • J
    Joel Brown DVMSep 1, 2025
    What does Er41 error mean on Alfa Plam LUCA 12?
    • M
      Madeline DavisSep 1, 2025
      The Er41 error on your Alfa Plam Pellet stove means there is an obstacle or large contamination in the pipe for primary air inlet. Wait for the furnace to shut down and then press P2 for more than 3 seconds. Also, check and clean the pipe for primary air inlet.
  • S
    Steven BrownSep 3, 2025
    What does Er12 error mean on Alfa Plam LUCA 12?
    • J
      Jennifer HernandezSep 3, 2025
      The Er12 error on your Alfa Plam Pellet stove indicates an ignition error or during the ignition phase adequate temp. of flue gases is not reached, or a faulty flue gas probe. To address this, wait for the furnace to shut down and then press P2 for more than 3 seconds.
  • P
    Paul SpencerSep 6, 2025
    What does Er15 error mean on Alfa Plam LUCA 12?
    • J
      Jason SkinnerSep 6, 2025
      The Er15 error on your Alfa Plam Pellet stove indicates a loss of power supply during furnace operation. Press and hold P2 for more than 3 seconds. Also, check to see if the system and installation are in order.
  • B
    baldwinrachelSep 8, 2025
    What does Er42 error mean on Alfa Plam LUCA 12?
    • Z
      Zachary KingSep 8, 2025
      The Er42 error on your Alfa Plam Pellet stove indicates too much air intake. Wait for the furnace to shut down and then press P2 for more than 3 seconds.