Operating Range of the APS punching unit for round holes with S233
Conversion factor of S233 for the processing of various materials.
APS 70 punching unit, Fmax = 310 kN
Punch diameter Ø = 18 mm
Material thickness S = 8 mm
Material C 45, R max = 800 N/mm²
APS 70 punching unit, Fmax = 310 kN
Punch diameter Ø = 21 mm
Material thickness S = 12 mm
Material S275, R max = 510 N/mm²
Calculation 1:
F = F (S233) x Factor (C 45 / S233)
F = 170 kN x 1,70 = 289 kN
F is smaller than Fmax
Calculation 2:
F = F (S233) x Factor (S275 / S233)
F = 298 kN x 1,09 = 324,8 kN
F is larger than Fmax
Punching power sufficient!
Punching power too low!
Please opt for our APS 120