Precision Gas Mass Flow Controllers
The Fastest Flow Controller Company in the World!
Operating Manual
MC-Series
MCS-Series
MCR-Series
WHISPER
MCV-Series

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Alicat Scientific MC Series and is the answer not in the manual?

Summary

MOUNTING

PLUMBING

POWER AND SIGNAL CONNECTIONS

INPUT SIGNALS

Analog Input Signal

Apply analog input to Pin 4 for setpoint or control.

RS-232; RS-485 Digital Input Signal

OUTPUT SIGNALS

RS-232; RS-485 Digital Output Signal

Connect RS-232/RS-485 output signals to computer serial port.

Standard Voltage (0-5 Vdc) Output Signal

0-5 Vdc output on Pin 6 for MC-Series controllers.

DISPLAYS AND MENUS

Main

Default display showing pressure, temp, setpoint, flow rates.

MAIN

Volumetric Flow Rate

Displays volumetric flow rate in selectable units.

Mass Flow Rate

Displays mass flow rate corrected to STP/NTP.

Choosing Engineering Units from Main Mode

SELECT MENU

CONTROL

Accesses setpoint source, loop variable, and PID tuning.

BASIC CONFIG

Configures gas selection, device units, STP/NTP references.

ADV SETUP

Adjusts sensor settings, unit ID, baud rate, display settings.

CONTROL

SETPT SOURCE

Selects how the setpoint is conveyed to the controller.

PID TUNING

LOOP TYPE

Selects the PID control algorithm (PD/PID, PD2I).

P, I, or D

Adjusts Proportional, Integral, and Differential terms of the PID loop.

TARES

BASIC CONFIG

GAS SELECT

Selects the gas or gas mix for accurate measurement.

DEVICE UNITS

STP;NTP

ADV SETUP

SENSOR SETUP

Adjusts zero deadband and averaging parameters.

COMM SETUP

DISP SETUP

MCV Controller Operating Notes

MCD Dual Valve Mass Controller Operating Notes

RS-232; RS-485 Output and Input

Sending a Setpoint via RS-232; RS-485

GAS SELECT > Standard

TROUBLESHOOTING

After installation, there is no flow.

Checks setpoint signal, grounding, and setpoint source.

Controller is slow to react to a setpoint change or imparts an oscillation to the flow.

Suggests PID tuning adjustment for slow response or oscillation.

RS-232; RS-485 Serial Communications is not responding.

Maintenance and Recalibration

Recalibration

Recommended yearly recalibration; contact for scheduling.

BATCH PROCESSING MODE

Accessory: BB9 Multi-Drop Box

Accessory: Flow Vision SC Software

Technical Data for Alicat MC and MCR Mass Flow Controllers

Technical Data for Whisper Low Pressure Drop Mass Flow Controllers

Technical Data for MCV & MCVS Mass Flow Controllers

Technical Data for MCP Moderate Flow Mass Flow Controllers

Technical Data for MCE and MCES Flow Mass Flow Controllers

Technical Data for Alicat MCD and MCRD Dual Valve Mass Flow Controllers

Technical Data for Alicat MCS and MCRS-Series Mass Flow Controllers

Technical Data for Alicat MCQ and MCRQ Mass Flow Controllers

Technical Data for PROFIBUS Meters, Gauges and Controllers

Power and Signal Connections

Details DB9 connector pinouts for PROFIBUS.

Eight Pin Mini-DIN Connector Pin-Outs

Locking Industrial Connector Pin-Outs

9 pin D-Sub Common Pinouts

15 pin D-Sub Common Pinouts

High Density 15 pin D-Sub Common Pinouts

Additional Information for Alicat CSA and ATEX Approved Devices

WARNINGS

Explosion hazard warnings for CSA/ATEX devices.

USE of Alicat instruments (...) in Class 1 Division 2 applications.

Special Conditions: CSA

USE of Alicat instruments (...) in applications requiring ATEX Class 1 Zone 2 Certification.

Special Conditions: ATEX

Gas Viscosity, Density and Compressibility:

Alicat Scientific MC Series Specifications

General IconGeneral
BrandAlicat Scientific
ModelMC Series
CategoryController
LanguageEnglish