1.
AILERON
ROLL
RATE
RHEA
Setting
Instruction:
1.After
entering
setting
mode,
STATUS
LED
flashes
once.
2.Aileron
and
elevator
rate
can
be
adjusted
independently.
3.Moving
the
aileron
stick
will
display
aileron
roll
rate
on
the
LED.
The
more
LEDs,
the
faster
the
roll
rate.
Moving
the
aileron
stick
can
increase
or
decrease
the
number
of
LEDs
that
lights
up
between
LED1
to
LEDS,
which
sets
the
aileron
roll
rate.
Same
method
is
used
to
adjust
the
elevator
flip
rate
when
elevator
stick
is
moved.
4.Elevator
flip
rate
is
a
ojusted
based
on
aileron
roll
rate.
When
the
difference
between
elevator
flip
rate
and
aileron
roll
rate
differs
by
20%
or
more,
3GX
will
automatically
adjust
until
the
error
rate
falls
within
range.
Therefore,
we
recommend
adjustment
aileron
roll
rate
first,
and
then
adjust
elevator
flip
rate.
5.Moving
the
related
control
stick,
LED
will
automatically
jump
to
the
set
rate
display
of
the
specific
stick
function.
For
example,
ones
the
aileron
stick,
LED1
to
LEDS
will
display
aileron
set
rate.
Moving
elevator
stick,
LED
to
LEDS5
will
display
elevator
set
rate.
e
TIERS
TATUSSOIBGEEOLA——
+
2.
BSE
be
OVER
OI
DID
BASIE
*
E:
3.
AMEE
S
AMET
RAGE
ZLEDISR
»
ERMSATRSMR
SHE
MEFTLUSMABLLEDI-LEDS
HERS
EMABMR
RGR
A
FED
A
AEACIEIS
BRAM
RRS
ZLEDISHE
»
TARAS
-
aE
al
BARRIS
AIRRGRSE20%
Yb
»
IGXSSHAZARRAEREROA
MAULAABBSRRGRE
-
RNR
5.
SNEREIFLEDGSMMBASISRED
»
PHS
MIEIS
+
LEDI~SHAAMSIRQE
-
MAE
LEDI~SBRTARREE
>
"|
iD
loc"
Å
A
Å
~
CD
i
mm)
CD
(Ee)
Bev
Oor
S53)
aw
Eee?
“ple
ELE
fy)
areis
vies
|
[Mode
1
Mode
2
ode
1
oa
S
2.
ELEVATOR
END
POINT
SETTING
ARRTERPRRE
Setting
Instruction:
1.Before
entering
elevator
and
aileron
limit
setting,
please
switch.the
transmitter
to
throttle
hold
mode
and
push
the
throttle
down
to
position
to
avoid
mechanical
interference
due
to
excess
travel
ranges
2.After
entering
setting
mode,
STATUS
LED
flashes
twice
3.After
entering
setting
mode,
elevator
may
deviate
assmuch
as
8
degrees
plus
compensating
rate
either
forward
or
back.
Moving
elevator
stick
can
adjust
servo
travel
limit:
For
example,
if
LED
shows
50%,
total
elevator
travel
range
is
8+0.5*8
=
12
degrees.
4.Generally
70%
is
suitable
for
most
helicopter
frame.
If
recommended
value
is
not
used,
please
adjust
setting
until
maximum
is
reached
without
mechanical
binding.
BERA
:
1
SEA
FH
ENDIE
RIEAN,
EREL,
DER
EOE
ESTRANGED
2A
BRIE
RS
TATUS
AIRES
IRMA
©
SHEA
RH
RAR
RBS
+
INRIA
STEN
EANET
Es
AR
TIZUIR
<
HIMDLEDEATEQE
50%
»
HPRALTLMTIZAIAS+0.5°8=12/E
©
4
(RDS
70%
LGA
SARA
EH
EN
ORNL
RE”
E
ESTE
E
FS
CORB
°
STATUS
Double
flash
STATUSPIHERIR
3,
AILERON
END
POINT
SETTING
@RiTHMRRE
Setting
Instruction:
1.After
entering
setting
mode,
STATUS
LED
flashes
3
times.
2.After
entering
setting
mode,
aileron
may
deviate
as
much
as
8
degrees
plus
compensating
rate
either
forward
or
back.
Moving
aileron
stick
can
adjust
servo
travel
limit.
For
example,
if
LED
shows
50%,
total
elevator
travel
range
is
8+0.5*8
=
12
degrees.
3.Generally
70%
is
suitable
for
most
helicopter
frame.
If
recommended
value
is
not
used,
please
adjust
setting
until
maximum
is
reached
without
mechanical
binding.
BERRA
:
1.3EA
ERIE
RS
TATUS
AUIS
SEPSIB
ER
©
2.38),
SEIS
ie
BSS
+N»
BORA
SRG
*
ENB)
RIEIST)
LSS
ART
SERR
-
PIRDLEDEAM
ERE
A350%
»
HAL
BAIAS+0.5°8=
12/8
<
3.-
MMS
7%
TAMARA
D
DEF
AE
URMERRAE
ARESRASETSTS
RE
+
STATUS
Flash
in
group
of
3