Setting of Payload and Alarm Limits
Payload 400 kg – 30000 kg
Overload (R1) 100 – 120 %
Full load (R2) 30 – 100 %
Underload (R3) Absolute values cannot be less than hysteresis (Hst)
Hysteresis (Hst) Can not be less than 75 kg and not more than 10 % of payload,
if the hysteresis is bigger than 80 kg
Load Calibration 50 – 120 %
Trailing cable compensation
Cable weight can be set between 0,9 - 4,8 kg/m
Maximum compensation is 250 kg for each load cell or 10 kg/m.
Quick guide for OSD 5 settings
Standard values:
Payload 1000 kg
Overload 1100 kg
Full load 900 kg
Setting of Zero Calibration value ZERO
Empty car.
Prog. + Zero
Zero
Cal.
Counts down to 0 on the display and weights.
Setting of Load Calibration value LOAD
Load at least 50 % of payload. To get the best result load 100 % of
payload.
Prog. + Zero
Load
Cal.
Set weight, for example payload 800 kg
Zero till 8
Load
Load 800 on the display
Cal.
Counts down to 0 on the display and weights.
– 4 –