10,O00W Generator
Operation
Pre-Operation Check
_NOTE
Fuel can damage paint and plastic. Be careful not to spill fuel when filing your fuel tank. Damage
caused by spilling fuel is not covered under warranty. Use unleaded gasoline with a pump
octane of 86 or higher. This engine is certified to operate on unleaded gasoline. Unleaded
gasoline produces fewer engine and spark plug deposits and extends exhaust system life,
Never use stale or contaminated gasoline or oil/gasoline mixture. Avoid getting dirt or water in
the fuel tank. Occasionally you may hear a light "Spark knock" or "pinging" (metallic
rapping noise) while operating under heavy loads. This is no cause for concern. If spark knock
or pinging occurs at a steady engine speed, under normal load, change brands of gasoline.
If spark knock or pinging persists, call our service center.
STARTING THE ENGINE/STOPPING THE ENGINE
Starting the Engine
1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to
start if a load is connected.
2. Turn the fuel valve lever to the ON position.
3. Put the choke to the CLOSED position.
4. Put the engine switch to the ON position.
5. Pull the starter grip lightly until resistance is felt, then pull briskly.
_NOTE
Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage
to the starter or housing.
6. As the engine warms up, slowly push the choke rod to the OPEN position.
Stopping the engine
In an emergency:
To stop the generator in an emergency, turn the engine switch to the OFF position.
In normal use:
1. Turn the AC circuit breaker to the OFF position.
2. Turn the engine switch to the OFF position.
3. Turn the fuel valve lever to the OFF position.
2O