EasyManua.ls Logo

Alpha Therm FOX-1SH User Manual

Alpha Therm FOX-1SH
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Product specifications and accessories may be changed at any time
based on improvements and other reasons.
Output
Sensor
CAUTION
SAFETY
Available
communi.
Range
Model
Cautions for your safety
series
series
Digital Humidity Controller
User's Manual
T/H sensor
H. sensor
Setting(UP)
Setting(DOWN)
Setting key(SET)
Output
Humidity display(FOX-1SH(R)model)
Temperature display(FOX-1SH(R)model)
Part name
1
model applied
sensor
Design of practical utility No. 0301508
Registration of desing No. 0316273
Humi./Temp. diplay mode
This product is a humidity controller, temperature is displayed in add-ons.
Caution1.
The temperature is display only, please note that control is not.
only
Setting range
Setting range
Sensor input correction menu
Setting range
Sensor heating menu
Present temp. & humi.
output deviation
changing menu
setting range
selection
of function
setting range
H(humidity)/d(dehumidity)
Humi./Temp. mode changing
Setting range
Ref 1. If press for more than 5 sec in the current state, the program setting mode to enter.
Ref 2. All the program after setting, if press for more than 3 sec or after 60 sec, automatically return
to
the current of humidity display after displayed O-K.
Present temp. & humi.
output deviation
changing menu
Sensor input correction menu
Setting range
selection
of function
setting range
H(humidity)/d(dehumidity)
setting range
Ref 1. If press for more than 5 sec in the current state, the program setting mode to enter.
Ref 2. All the program after setting, if press for more than 3 sec or after 60 sec, automatically return
to
the current of humidity display after displayed O-K.
Version 0.96(2015.08.25)
1
1
% %
.
Model Composition
Question and Answer IconNeed help?

Do you have a question about the Alpha Therm FOX-1SH and is the answer not in the manual?

Alpha Therm FOX-1SH Specifications

General IconGeneral
BrandAlpha Therm
ModelFOX-1SH
CategoryController
LanguageEnglish

Summary

Model Composition

Safety and Cautions

General Safety Precautions

General safety precautions and warnings for product operation.

Critical Safety Instructions

Critical safety instructions and handling guidelines for device operation.

Electric Shock Danger

Warning about electric shock risks during operation and installation.

Part Identification

Connection Diagrams

FOX-1SH/FOX-1SHR Wiring

Wiring diagram and connection details for FOX-1SH and FOX-1SHR models.

FOX-1H Wiring

Wiring diagram and connection details for the FOX-1H model.

Program Settings (FOX-1SH(R))

User Humidity Setting

Procedure for setting user-defined humidity values in the controller.

Humidity/Temperature Display Mode

How to switch between humidity and temperature display modes.

Program Setting Mode

Steps and options for configuring program settings on the controller.

Program Settings (FOX-1H)

User Humidity Setting

Procedure for setting user-defined humidity values in the controller.

Program Setting Mode

Steps and options for configuring program settings on the controller.

Detailed Explanation

Temperature Deviation Setting (di F)

Explanation of setting temperature deviation for stable ON/OFF control.

Function Selection (LYP)

How to select the dehumidify (d) or humidify (H) function.

Humidity Correction (Cor)

Function to correct displayed humidity values to match actual measurements.

Sensor Heating Element (HEL)

How the sensor heating function prevents dew formation.

RS485 Address Setting (Adr)

Setting the communication address for RS485 interface.

RS485 Speed Setting (66AU)

Configuring the communication speed for RS485 interface.

Size & dimension

Setting range & Set value when deliver

Sensor's specifications

DS-SH Series Sensor Specs

Technical specifications for DS-SH series humidity sensors.

HS220 Sensor Specs

Technical specifications for the HS220 humidity sensor.

Communication interface (FOX - 1SHR)

Application for humidity controller

Dehumidifier Operation Example

Example of setting up the controller for dehumidifier operation.

Humidifier Operation Example

Example of setting up the controller for humidifier operation.

Error Handling and Warranty

Error Message Interpretation

Explains error codes and troubleshooting steps for controller malfunctions.

Product Warranty Information

Information regarding the product's warranty period and terms.

Manual Download Information

Instructions for downloading the English version of the manual.