EasyManua.ls Logo

AlphaLab TriField TF2 - AC Electric Field Detection

AlphaLab TriField TF2
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The AC Magnetic Mode uses three ferrite-core coils, pointing in the X, Y, and Z directions, located
near the top of the meter. The X, Y and Z signals are combined into a true magnitude of the
ȴHOGVWUHQJWKLQGHSHQGHQWRIZKLFKGLUHFWLRQWKHPHWHULVSRLQWHG0D[LPXPUDQJHLV
P*ZLWKUHVROXWLRQRIP*DQGDFFXUDF\RIsRIUHDGLQJDW+]DQG+]$IUHTXHQF\
response graph of Standard and Weighted modes is on page 7.
ΖQPRVWKRPHVRURɝFHVVRPHDUHDVDUHȊKRWȋVSRWVZLWKKLJKUHDGLQJV0RVWRIWHQWKLVLV
FDXVHGE\PDJQHWLFȴHOGVZKLFKFRPHODUJHO\IURPXQSDLUHGLQWHUQDOZLULQJ&RQWUDU\WR
popular belief, power transmission lines and transformers do not generally contribute as
PXFKPDJQHWLFȴHOGLQGRRUVDVGRHVLQWHUQDOZLULQJ7KLVLVEHFDXVHKLJKYROWDJHOLQHVFDUU\
relatively low current, and transformers are shielded. Other magnetic sources include video
GLVSOD\VȵXRUHVFHQWOLJKWVOLJKWGLPPHUVWUDQVIRUPHUVWKDWDUHLQVLGHFRQVXPHUGHYLFHV
HOHFWULFEODQNHWVKHDWHUVDQGDQ\WKLQJZLWKDPRWRU0XFKRIWKHWRWDOȴHOGVWUHQJWKLVIURP
IUHTXHQFLHVWKDWDUHKDUPRQLFVRUPXOWLSOHVRI+]+]+]HWF&DUVHVSHFLDOO\QHDU
WKHIURQWȵRRUERDUGDQGPRWRUF\FOHVKDYHIDLUO\VWURQJȴHOGVDWIUHTXHQFLHVKLJKHUWKDQ+]
AC Electric Field Detection
7RPHDVXUHWKHH΍HFWRIDQ$&HOHFWULFȴHOGRQWKHKXPDQERG\WXUQWKHNQREWRWKH:HLJKWHG
ELEC setting and hold the meter at the location to be measured. For standard technical AC
HOHFWULFȴHOGPHDVXUHPHQWWXUQWKHNQREWRWKH6WDQGDUG(/(&VHWWLQJ
<RXUERG\FDQHDVLO\VKLHOGHOHFWULFȴHOGVWKHUHDGLQJLVORZHULI\RXFRYHUWKHWRSVXUIDFHRIWKH
meter with your hand. Also, the presence of your hand at the back of the meter compresses the
HOHFWULFȴHOGPDNLQJLWUHDGVRPHZKDWKLJKHUWKDQLIWKHPHWHUZHUHVXVSHQGHGIURPDVWULQJ
RUKHOGRQDERDUGDZD\IURP\RXΖQHLWKHUFDVHWKHWUXHHOHFWULFȴHOGQHDUWKHPHWHUZLOOEH
displayed.
The AC Electric Mode uses a metal plate sensor under the top of the meter. Circuitry similar to
WKHPDJQHWLFVHFWLRQFRQYHUWVWKHVLJQDOVLQWRDQHOHFWULFȴHOGVWUHQJWKMaximum range is 1000
9PZLWKUHVROXWLRQRI9PDQGDFFXUDF\RIsRIUHDGLQJDW+]DQG+]$IUHTXHQF\
response graph of Standard and Weighted modes is on page 7.
$IHZDUHDVLQPRVWKRPHVUHDGKLJKRQWKHHOHFWULFȴHOGVHWWLQJ7KHVHLQFOXGHDUHDVQHDU
LPSURSHUO\JURXQGHGHTXLSPHQWWKHIURQWRIYLGHRGLVSOD\VDQGȵXRUHVFHQWOLJKWV
4