Alstom FKG1X - Commissioning; Pre-commissioning Inspections

Alstom FKG1X
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Commissioning
Pre-
-
commissioning
inspections
G34
-
-0
01EN04
1/8
02--2011
© ALSTOM 2010. All rights reserved. Informat
ion contained in
this document is indicative only. No
representati
on or
warrant
y is
given or should
be
relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is
provided without liabili
ty and
is subject to
change without notice. Reproduction, use or disclosure to
third parties, without express writt
en authority, is
strictly prohibited.
GRID
Presentation
Introduction
After
installatio
n
of
the
bay
,
completio
n
of
all
earth
circuit
and
electrica
l
con-
nections
,
it
is
necess
ary
to
perform certain pre-
-commissioni
ng inspections.
These ins
pections
should
be perfo
rmed with the
appara
tus ready
to be
com-
missioned (energized), in other words.
D
L
V electrical circuits conf
orming, in voltage and type, with t
he low-
-volt
age
diagrams and rating plate of the apparatus.
D
SF
6
envelopes at rated SF
6
pressure.
NOTE
:
Ra
ted
pr
es
su
re
,
pr
es
su
re
of
eq
ui
pm
en
t
aft
er
SF
6
gas
filli
ng.
D
Flexi
ble connections linking circuit-
-breaker t
o busbar installed.
Reminder
The
me
as
ure
men
t
va
lu
es
de
man
de
d
he
rea
fter
ar
e
to
be
tak
en
du
rin
g
the
tes
t
an
d
in
sp
ec
tio
n
pr
og
ra
mme
pri
or
to
co
mmi
ss
io
ni
ng
an
d
ch
ec
ke
d
wi
th
the
va
l-
ues of the acceptance criteria” and checking points end of this sheet, then
en
ter
ed
in
the
pr
e-c
om
mis
sio
ni
ng
tes
t
rep
ort
(R
ES
...,
se
e
su
mma
ry
for
re
fer
-
ence)
.
The document RES
... which should then be sent for approval
to
ALSTOM Grid
S.A. Customer Service
.
.
If,
ho
we
ve
r
,
the
va
lu
es
do
no
t
co
nfo
rm
wi
th
tho
se
for
es
ee
n
in
the
acceptation criteria or general characteristics, contact :
ALSTOM Grid S.A. Customer Service.
Caution
DURING
OPERA
TIONS
REQUIR
ED
AS
P
ART
OF
INSPE
CTION
PRO-
GRAMME PRIOR TO COMMIS
SIONING, ALL POSSIBLE SAF
ETY
PRE-
CAU
TION
S
SHO
ULD
BE
T
AKE
N
TO
PRO
TEC
T
PER
SONN
EL
WORK
ING
ON THE EQUIPMENT.
See “Product safety sheets”, PS0000EN”
In this module
This
module
contains
the
followin
g
checkin
g
inspectio
ns :
I
n
s
p
e
c
t
i
o
n
s
P
a
g
e
SF
6
g
a
s
2
O
p
e
r
a
t
i
n
g
d
e
v
i
c
e
o
f
c
i
r
c
u
i
t
-
-
b
r
e
a
k
e
r
3
T
e
s
t
o
p
e
r
a
t
i
o
n
s
o
f
c
i
r
c
u
i
t
-
-
b
r
e
a
k
e
r
4
O
p
e
r
a
t
i
n
g
d
e
v
i
c
e
o
f
d
i
s
c
o
n
n
e
c
t
o
r
(
s
)
5
T
e
s
t
o
p
e
r
a
t
i
o
n
s
o
f
d
i
s
c
o
n
n
e
c
t
o
r
(
s
)
6
P
r
e
p
a
r
i
n
g
f
o
r
r
e
s
u
m
p
t
i
o
n
o
f
s
e
r
v
i
c
e
7
F
i
n
i
s
h
8

Related product manuals