MANUAL DE INSTALACIÓN
®
Certified to NSF/ANSI 61
Español página 2
English page 9
TANQUES PRECARGADOS
ALTAPRO XLB20, ALTAPRO XLB26, ALTAPRO XLB45, ALTAPRO XLB65, ALTAPRO XLB86, ALTAPRO XLB119,
ALTAPRO XLT20, ALTAPRO XLT26, ALTAPRO XLT45, ALTAPRO XLT65, ALTAPRO XLT86 Y ALTAPRO XLT119
SERIE PRO-XLB Y PRO-XLT
Question and Answer IconNeed help?

Do you have a question about the ALTAMIRA PRO-XLB Series and is the answer not in the manual?

Overview

The Altamira Pro-XLB and Pro-XLT series are pre-charged water system tanks designed for use in various water supply systems, including those with submersible and jet pumps. These tanks are engineered to provide efficient and reliable water storage, contributing to the longevity and performance of the overall water system.

Function Description:

The primary function of the Altamira Pro-XLB and Pro-XLT tanks is to store water under pressure, reducing the frequency of pump starts and stops. This action helps to extend the life of the pump and other components of the water system. The tanks operate by utilizing a sealed-in-place butyl diaphragm (A) that separates the water chamber (C) from the air chamber (B). As water enters the tank, the air above the diaphragm is compressed, creating pressure. When the pump shuts off, the compressed air pushes water out of the tank into the system. This process ensures a steady supply of water and minimizes pressure fluctuations.

The tanks are designed to maintain a consistent water flow and pressure, which is crucial for household and commercial applications. By acting as a buffer, they prevent the pump from cycling on and off excessively, which is a common cause of premature pump failure and increased energy consumption. The pre-charged design means that the tank comes with a factory-set air charge, which can be adjusted to match the specific cut-in pressure of the pump.

Important Technical Specifications:

The Altamira Pro-XLB and Pro-XLT tanks are designed for a maximum working pressure of 125 PSI (8.6 kg/cm²). The factory pre-charge pressure is typically 38 PSI (2.6 kg/cm²), but it is crucial to adjust this to 2 PSI below the pump's cut-in pressure for optimal performance. The tanks are suitable for water temperatures up to 120°F (49°C).

The tanks are available in various sizes, indicated by models such as ALTAPRO XLB20, XLB26, XLB45, XLB65, XLB86, XLB119, and ALTAPRO XLT20, XLT26, XLT45, XLT65, XLT86, XLT119. These different capacities allow for selection based on the specific needs of the water system, ensuring adequate water storage for various demand levels. The internal components, particularly the diaphragm, are made from materials designed to prevent corrosion and ensure the purity of the stored water. The tanks are NSF/ANSI 61 certified, indicating compliance with standards for drinking water system components.

Usage Features:

Installation of the Altamira Pro-XLB and Pro-XLT tanks involves connecting them to the water supply system, typically near the pump. For submersible pump installations, the tank is usually located above ground, while for jet pump installations, it can be placed in various locations, provided the piping is correctly routed. It is essential to install a pressure relief valve and a pressure gauge to monitor and control the system pressure.

Before initial use, the tank's pre-charge pressure must be checked and adjusted. This involves using an air pressure gauge (similar to an automotive tire gauge) to measure the air pressure in the tank's air valve. The pressure should be set to 2 PSI below the pump's cut-in pressure. Failure to do so can lead to excessive pump cycling or inadequate water delivery.

The tanks can be connected in parallel for larger systems requiring increased storage capacity. This involves installing multiple tanks on a common manifold, ensuring that the total volume meets the system's demands. When connecting multiple tanks, the manifold piping should be sized appropriately to avoid flow restrictions.

Maintenance Features:

Regular maintenance is crucial for the optimal performance and longevity of the Altamira Pro-XLB and Pro-XLT tanks. The primary maintenance task involves periodically checking and adjusting the tank's pre-charge air pressure. This should be done at least once a year, or more frequently if the pump starts cycling excessively. To check the pressure, the pump must be turned off, and the system drained of water. The air pressure in the tank is then measured and adjusted as needed.

It is important to inspect the tank for any signs of corrosion, leaks, or physical damage. Any visible damage should be addressed promptly to prevent further issues. The pressure relief valve should also be checked periodically to ensure it is functioning correctly and not stuck. If the tank is installed in an area prone to freezing temperatures, adequate insulation or heating should be provided to prevent water inside the tank from freezing, which can cause rupture and damage.

In case of trouble, such as the pump cycling too frequently or insufficient water pressure, a systematic troubleshooting approach is recommended. This includes checking the air charge in the tank, inspecting the pressure switch settings, and examining the system for leaks. If the issue persists, consulting a qualified technician is advisable. The warranty for these tanks typically covers defects in materials and workmanship for a specified period, provided the installation and maintenance guidelines are followed.

ALTAMIRA PRO-XLB Series Specifications

General IconGeneral
BrandALTAMIRA
ModelPRO-XLB Series
CategoryWater Heater
LanguageEnglish