USE AND CARE GUIDE
THANK YOU
v.953L.01
GOSSAMER 52 INCH CEILING FAN
Questions, problems, missing parts?
Before returning to the store, call, text, or email Customer Service
9 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 5 p.m., EST, Saturday.
GOSSAMER 60 INCH CEILING FAN
1-833-888-FANS (3267)
support@altitudefans.com
www.altitudefans.com

Questions and Answers

  • K
    kathy89Aug 11, 2025
    What to do if altitude Fan remote control is not working?
    • M
      miguel65Aug 11, 2025
      If the remote control for your altitude Fan isn't working, make sure you haven't connected the fan to any wall-mounted variable speed controls. Also, verify that the dip switches in the remote control and receiver are set to the same frequency.
  • K
    Kirk DuncanAug 16, 2025
    Why does my altitude GOSSAMER 953L52MWH Fan wobble?
    • J
      Jorge MillerAug 17, 2025
      If your altitude Fan wobbles, first ensure that all blade and blade arm screws are securely tightened. A common cause of wobble is unequal blade levels. To check this, measure the distance from the tip of each blade to a point on the ceiling directly above. The deviation in measurements should be within 1/8 inch. Allow the fan to run for 10 minutes after adjustments.
  • D
    Dr. Michelle CampbellAug 22, 2025
    How to fix a noisy altitude GOSSAMER 953L52MWH Fan?
    • P
      Patrick CurtisAug 23, 2025
      If your altitude Fan sounds noisy, try these steps: * Ensure all motor housing screws are snug. * Check that the screws attaching the fan blade arm to the motor hub are tight. * Confirm wire nut connections aren't rattling. * Allow a 24-hour "breaking-in" period for new fans. * If using a light kit, tighten the glassware screws and ensure the bulb is secure. * Make sure there's a small gap between the ceiling and the canopy. * Verify your ceiling box is secure, using rubber isolator pads between the mounting bracket and outlet box.
  • A
    Ashley WareAug 29, 2025
    How to troubleshoot an altitude Fan that will not start?
    • N
      ngarzaAug 29, 2025
      If your altitude Fan will not start, check the main and branch circuit fuses or breakers. Also, inspect the line wire connections to the fan and the switch wire connections in the switch housing. Finally, ensure that the dip switches on the remote control and receiver are set to the same frequency.
  • S
    Stacey JonesSep 4, 2025
    Why does my altitude GOSSAMER 953L52MWH move backwards and forwards when turned on?
    • C
      Courtney PerezSep 4, 2025
      This is normal for DC motor fans. The partial movement during start-up is due to the DC motor aligning its internal magnetic poles for optimal operation. This design saves electricity and reduces fan noise compared to standard AC motor fans.