- 8 - AL1002ULADAJ
Hookup Diagram:
Fig. 3
These circuits are used to monitor AC and
Bat Fail and will cause a simultaneous trouble
condition to the FACP's IN1 and IN2 (Non-Supervised)
4-wire Smoke
Detector
+
--
+
--
4-wire Smoke
Detector
Fire Alarm
Control Panel
(FACP)
EOL Power
Supervision Relay
(Not Supplied)
EOL
Resistor
from FACP
SW1
-- DC +
SW2
+ OUT1 --
OUT1 OUT2 OUT3 OUT4
INP1 INP2
FAULT
NC CNOC "FAULT" NC
OUT1 OUT3
OUT2 OUT4
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
IN1+
IN1--
IN2--
IN2+
C "DRY1" NC
RET1+
RET1--
RET2--
RET2+
C "DRY2" NC
+ OUT2 --
+ OUT3 --
+ OUT4 --
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
-- AUX +
UPPER TERMINALS
LOWER TERMINALS
Addressable Control
Module Trigger Output
See Note 2
(Non-Supervised)
RESET
Supervised
Non-Supervised
Input from
Power Supply
BAT FAIL
AC FAIL
DC AC
NC C NO NC C NO
AC LOCAL
NC C NO
L
N
6.3A 250V
Digital Communicator
or Local Annunciator
Dry output Contact
(Form "C" contacts)
Power-Limited Outputs
2.5A per output in alarm
Total = 10A
(Supervised)
ON
AC DELAY
OFF 2 Hours
ON 1 minute
ON
1
ON
1
AC FAIL
NC C NO
BAT FAIL
NC C NO
Fig. 3a
These circuits are used to monitor AC and
Bat Fail and will cause a simultaneous trouble
condition to the FACP's IN1 and IN2 (Non-Supervised)
4-wire Smoke
Detector
+
--
+
--
4-wire Smoke
Detector
Fire Alarm
Control Panel
(FACP)
EOL Power
Supervision Relay
(Not Supplied)
EOL
Resistor
from FACP
SW1
-- DC +
SW2
+ OUT1 --
OUT1 OUT2 OUT3 OUT4
INP1 INP2
FAULT
NC CNOC "FAULT" NC
OUT1 OUT3
OUT2 OUT4
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
IN1+
IN1--
IN2--
IN2+
C "DRY1" NC
RET1+
RET1--
RET2--
RET2+
C "DRY2" NC
+ OUT2 --
+ OUT3 --
+ OUT4 --
INPUT SELECT
TEMPORAL
STROBE SYNC
IN > OUT SYNC
-- AUX +
UPPER TERMINALS
LOWER TERMINALS
Addressable Control
Module Trigger Output
See Note 2
(Non-Supervised)
RESET
Supervised
Non-Supervised
Input from
Power Supply
BAT FAIL
AC FAIL
DC AC
NC C NO NC C NO
AC LOCAL
NC C NO
L
N
6.3A 250V
Digital Communicator
or Local Annunciator
Dry output Contact
(Form "C" contacts)
Power-Limited Outputs
2.5A per output in alarm
Total = 10A
(Supervised)
ON
AC DELAY
OFF 2 Hours
ON 1 minute
ON
1
ON
1
Fig. 3c
Trouble Memory
Reset Button
Fig. 3b
Common trouble
Input/Output
NC CNOC "FAULT" NC