Flood and Temp Sensor is an integrated environmental
sensor. It detects ood conditions and reports extreme
temperatures.
Features
Titanium probes for unmatched corrosion immunity
IP67 rated waterproof enclosure
GORE
®
vent to prevent seal failure
5 year warranty
Enroll by placing the panel into wireless enrollment mode and
removing the battery tabs, tampering the sensor, or manually
entering the sensor ID.
Loop Conguration
Loop 1 = Freeze
Loop 2 = Heat
Loop 3 = Flood
Install by placing the sensor in the location requiring ood or
temperature detection. If desired, the wall clip can be used to
secure the sensor.
Optional Screw Mounting
Remove the wall clip from the sensor’s body.
Secure the clip to a wall, baseboard or cupboard
using a #6 screw.
Slide the sensor’s body down onto the wall clip
until it snaps into place.
Detects water pooled under the sensor and reports extreme
temperature conditions.
Temperature Trip Points
Heat alarms when over 100°F (38°C)
Heat restores when under 97°F (36°C)
Freeze alarms when under 45°F (7°C)
Freeze restores when over 48°F (9°C)
To replace the batteries, insert a at blade screwdriver into
the front slot and twist. Slide both old batteries out and the
new batteries in. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
I
N
S
T
A
L
L
G
U
I
D
E
I
Verify proper enrollment and operation using your control panel’s installation manual.
Front slot
Mounting Screw Hole
Wall Clip
RE218 Flood & Temp Sensor
Honeywell
®
Compatible