Always “On” UPS DC UPS Systems User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Always “On” UPS Systems Inc.
®
User Manual
Version 1.0
DC UPS SYSTEMS
DC UPS
SYSTEM
UPC Order Code
825433 00420 825433 00425
Phase Single
Voltage 120 or 220VAC Nominal (+10% -13%)
Input
Frequency 47 – 63 Hz
Voltage (nominal) 12VDC 12VDC
Voltage Range 10.2 - 13.8VDC 10.2 - 13.8VDC
Output Current 3A Max (other configurations available)
Output
Transfer Time 0 ms
Current 0.5A
Charging
System
Voltage 13.8VDC
Type Sealed, maintenance-free, lead acid
Capacity 12V 5Ah 12V 26Ah
Runtime Dependant on load(s)
Number of Batteries 1
Battery Low Trip Point 10.8-10.9VDC
Batteries
Charging Time 4 hours to 90% 16-20 hours to 90%
Protection
Output short, Overload, I/O noise, spike and
transient, RFI/EMI filter full time suppression
and FCC Class, Surge/Transient (6500A, 320J)
IEEE C62.41 Cat. A
LED AC Present / Charging / Output / Low Battery
Indicators
Audible Alarm YES
Operating Temperature 0°C to 40°C
Environmental
Humidity 5-95% non condensing
Container Rating NEMA 1
Mounting Tower
Dimensions (WxDxH) 10.5"x6.1"x2.5" 10.5"x11.5"x8"
Physical Data
Weight 3.0kg (6.6lbs) 12kg (30lbs)
Always “On” UPS Systems Inc.
Bldg 1 – 150 Campion Road, Kelowna, BC, V1X 7S8
FOR MORE INFORMATION CALL TOLL FREE AT 1-877-259-2976 Ext 451.
Question and Answer IconNeed help?

Do you have a question about the Always “On” UPS DC UPS Systems and is the answer not in the manual?

Always “On” UPS DC UPS Systems Specifications

General IconGeneral
TypeDC UPS
Battery TypeTypically Lithium-ion or Lead-acid
Protection FeaturesOverload protection, short circuit protection, over voltage protection, under voltage protection
Communication InterfaceVaries by model (typically USB, RS232, or dry contact)
DimensionsVaries by model
WeightVaries by model
TopologyVaries by model (likely Standby or Line-Interactive)
Input VoltageVaries by model (typically 12V DC, 24V DC, or 48V DC)
Output VoltageVaries by model (typically 12V DC, 24V DC, or 48V DC)
Power CapacityVaries by model (typically from 10W to 200W or higher)
EfficiencyVaries by model (typically 85% to 95%)
Operating TemperatureVaries by model (typically 0°C to 40°C or -10°C to 50°C)

Summary

Introduction to DC UPS Systems

System Installation Procedures

Inspection Before Installation

Check for shipping or product damage upon receipt and contact the factory if damaged.

Optimal Placement Guidelines

Install in a controlled environment with adequate airflow, free of dust and moisture.

Connecting the System

Connect the input power cord to the system and the load to the terminal strip.

System Operation

Turning the System On

Move the power switch to the 'on' position. The LED will light up.

Turning the System Off

Move the power switch to the 'off' position to stop output power.

System Alarms

Low Battery Alarm

The system will beep once every four seconds when in low battery mode.

Overload Alarm

A continuous beep indicates an overload until it is removed or the system shuts down.