APPENDIX B. ELECTRICAL AND DATA CONNECTIONS
IS-300CA INVERTER POWER SUPPLY
990-418 B-9
Pin
No.
Name
EtherNet/IP
TM
Model
Description
1
2
ANALOG IN1+
ANALOG IN1-
0 - 10VDC Analog input 1
3
4
ANALOG
OUT1+
ANALOG
OUT1-
0 - 10VDC Analog output 1*
2
5
6
ANALOG IN2-
ANALOG IN2-
0 - 10VDC Analog input 2
7
8
ANALOG
OUT2+
ANALOG
OUT2-
0 - 10VDC Analog output 2*
2
9
10
CURRENT
COM-
CURRENT
OUT+
Current output (0 - 10 VDC)*
2
V
out
= I
out
/ 5000
11
12
VOLTAGE
COM-
VOLTAGE
OUT+
Voltage output (0 - 10 VDC)*
2
V
out
= V
feedback
/ 2
14
INT +24VDC
GND (COM)
COM pin. This pin is internally connected to the +24VDC GND
15
16
17
18
RETRACTION 1
RETRACTION 2
BACK STEP
STEP MODE
YES
EtherNet/IP
TM
unit comes default with signal Sourcing. Customer
can configure to signal Sinking, but EtherNet/IP
TM
will be disabled
Advanced unit comes default with Signal Sinking. Customer can
configure to signal Sourcing,
19
+24VDC OUT MAX CURRENT DRAW: 100mA