5.39 Nett flash inhibit
Display: NEtt FLSH
Range: on or OFF
Default Value: OFF
Nett value display mode - the nett value is only seen when the remote input R.INP or P button
Pbut function is set to tARE and can therefore toggle between gross and nett displays. The
NEtt FLSH function can be set to on or OFF. If set to on then the message NEtt will flash
briefly approximately every 6 seconds when the operator toggles to a nett display to remind the
operator that a nett value is being viewed. If set to OFF then the message NEtt will flash briefly
once only when the operator toggles to the nett value.
5.40 Access mode
Display: ACCS
Range: OFF, EASY, NONE or ALL
Default Value: OFF
Access mode - the access mode function ACCS has four possible settings namely OFF, EASY,
NONE and ALL. If set to OFF the mode function has no effect on alarm relay operation. If set
to EASY the “easy alarm access” mode will be activated. Refer to “Easy alarm relay adjustment
access facility” section. If set to NONE there will be no access to any functions via FUNC mode,
entry via CAL mode must be made to gain access to alarm and calibration functions. If set to ALL
then access to all functions, including calibration functions, can be gained via FUNC mode.
5.41 Setpoint access mode
Display: SPAC
Range: A1, A1-2 etc.
Default Value: A1
Setpoint access - seen only if more than 1 relay fitted. Sets the access via FUNC mode and “easy
alarm access” mode to the alarm relay setpoints. The following choices are available:
A1 - Allows setpoint access to alarm 1 only.
A1-2 - Allows setpoint access to alarms 1 and 2 only.
A1-3 - Allows setpoint access to alarms 1, 2 and 3 etc. up to the maximum number of relays
fitted.
The remote input function (R.INP) must be set to SP.AC for this function to operate. Note:
Only the setpoints which have been given a value will be accessible e.g. if A1Hi is set to OFF
then there will be no access to the A1Hi function when SPAC is used.