26
EN
NOTICE
Forward voltage typically indicates
0.4 to 0.7 V. A shorted diode indicates near 0 V
and an open diode indicates OL in both polarities.
Temperature measurement
Insert the thermocouple probe adapter (P) with
the black connector into the negative COM
(black) terminal (I) and with the red connector
into the positive V (red) terminal (M).
Connect the thermocouple probe (Q) to the
thermocouple probe adapter (P). The polarity
marking of the probe (Q) must correspond to
the marking of the adapter (P). The probe pins
are made in varying sizes to avoid a wrong
connection.
Set the function switch (K) to the TEMP/°C/°F
position.
Press the MODE/VFD button (H) to change the
temperature unit.
Touch the thermocouple probe tip to the
component under test.
The stabilized value on the display (F) is read as
the actual reading.