30
EN
DC current
Range
Resolution
Accuracy
60A 10mA ±2.0 % f.m.* ±8digits
600A 100mA ±2.5 % f.m.* ±8digits
Overrange protection: Maximum input 600A.
AC true rms voltage (with VFD)
Range
Resolution
Accuracy
6V 1mV
±1.2 % f.m.* ±5digits60V 10mV
600V 100mV
1000V 1V ±1.5 % f.m.* ±5digits
• Variable frequency drive measurement
ACvoltage range: 100V – 600V.
• AC voltage bandwidth:
50 to 1000Hz (sinusoidal);
50/60 (all waves)
• Accuracy specified from 5% to 100% of the
measuring range.
• Maximum input: 1000V AC rms.
• PEAK maximum input: 1000V.