10
Cleaning the air intakes and ventilation openings
Regularly clean the air intakes and ventilation openings. Use a flexible brush.
Troubleshooting
Problem Solution
Product is switched on but
does not heat.
• Check if the cookware is suitable for induction
cooking.
• Place the cookware in the middle of the
induction cooking plate (B).
Heating stops suddenly
during operation.
• Product overheated. Let it cool down for
15minutes.
• Clean the air intakes and ventilation openings.
• If the problem persists, refer to the following
failure code table.
Failure code Problem Solution
E6
Product
overheated.
• Let the product cool down for
15minutes.
E7, E8
Incorrect power
supply rating.
• Connect the product to a suitable
power source as indicated on the
rating label.
E1, E2, E4, E5,
U1, Eb
Other problem. • Contact the customer service.