Installation and Operation
6
MENU ONE SETTINGS: RANGE DEFAULT
SETTING
TITLE: Eight characters; A–Z, 0–9, :, /, +, -, space CAM1 thru CAM4
DWELL: 0–99 seconds 01S (One second)
TIME: HH:MM:SS; DATE: MM-DD-YY or DD-MM-YY (PAL) ON
TILE: ON or OFF ON
MENU TWO SETTINGS: RANGE DEFAULT
SETTING
SENSOR: Attached device is OPEN (NO) or CLOSED (NC) OPEN
STATUS: Unit response to attached sensor is ON or OFF ON
ALARM SENSITIVITY: Shortest pulse that triggers alarm response; 0.1
seconds to 0.8 seconds
0.3S
ALARM DURATION: Response after end of input; 0 seconds to
59 minutes
10S
AUDIBLE ALARM: Sound during alarm; ON or OFF ON
VIDEO LOSS: Video loss triggers alarm; ON or OFF ON
SECURITY LOCK: Disables front panel controls; ON or OFF OFF
UNIT ID (Premium units only): Unit number returned at TX pin of
remote connector; control up to nine units, 1–9
0 (no ID)