EasyManua.ls Logo

American Energy Systems Avent User Manual

Default Icon
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Avent
WOOD PELLET STOVE
NOTE: THESE INSTRUCTIONS MUST BE SAVED for future reference
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING
STOVE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY
INJURY OR EVEN DEATH.
IMPORTANT: Always contact your local dealer/installer with questions before contacting the factory.
When you call have your serial number, purchase date, who installed the unit and a list of questions.
AMERICAN ENERGY SYSTEMS, INC. GRANTS NO WARRANTY, IMPLIED OR STATED, FOR THE
INSTALLATION OR MAINTENANCE OF THE STOVE AND ASSUMES NO RESPONSIBILITY FOR ANY
CONSEQUENTIAL DAMAGE(S).
AMERICAN ENERGY SYSTEMS, INC. -150 Michigan Street SE - HUTCHINSON, MINNESOTA 55350
Web Site: www.hearthdirect.com
Rev. date 08/06/03
9 When installing your Avent Wood Pellet stove, particular attention needs to be made in regards to fire
protection. If the unit is not properly installed, a house fire may result. For your safety, follow the
installation and operation instructions provided. Contact local building or fire officials about restrictions
and installation inspection requirements in your area.
9 Read the operations and fuel section of this manual before plugging in your unit.
9 Always unplug the unit before attempting any service work.
9 Do not connect the unit to a chimney flue already serving another appliance.
9 When installing the chimney pipe to the unit, it is important to remember that the unit operates on a
positive pressure and the chimney on a positive pressure. All chimney connections, elbows and fittings
must be airtight. (proper venting practices must be followed. Consult with a venting professional)
9 Ashes must be disposed of in a metal container with a tight fitting lid.
9 All minimum clearances to combustibles must be followed.
9 The Avent Wood Pellet Stove is tested for operation with wood pellets with ash content of no more than
2%. It is recommended that wood pellets with an ash content of 1% or less be used for efficient
operation of this unit. For use with wood pellets, cherry pits, olive pits or other pelletized fuel.
9 It is important to use fuel that is clean, dry and consistent. Make sure that your supplier is giving you
the same fuel each time that you purchase. It is recommended that you purchase your entire heating season
supply of fuel at one time so that the fuel will be the same.
9 A voltage surge protector or ground fault outlet is required for this unit. The warranty will be
voided if surge protection is not installed before operating this unit.
9 A grounded outlet must be provided with proper polarity. A constant 115 volt, 60 cycles must be
provided for proper operation or the warranty of this appliance will be forfeited.
9 Special attention needs to be taken to clean out the top heat exchangers of this unit on a regular
basis. The fly ash from the venting settles on the top heat exchangers and must be cleaned off to
keep the unit operating properly. Check for plugging every one-two weeks or when needed.
9 If unit is not operated for extended periods of time (like summer) unplug the unit and disconnect the
battery to assure long life of electrical components.
9 This appliance has been tested to UL1482/ ASTM E 1509 standards
OWNER’S MANUAL
Installation – Operation – Maintenance Instructions

Questions and Answers:

American Energy Systems Avent Specifications

General IconGeneral
BrandAmerican Energy Systems
ModelAvent
CategoryPellet stove
LanguageEnglish

Summary

Avent Technical Data

Estimated Fuel Feed Rate Chart

Details fuel consumption rates for different settings and fuel types.

Specifications

Heat Output and Fuel Storage

Lists key performance metrics like BTU/HR and fuel capacity.

Clearances to Combustibles

Specifies minimum safe distances to walls and floors.

Safety Steps

General Safety Precautions

Covers essential safety measures for installation and operation.

Fuel and Fire Safety

Guidelines for safe fuel handling and fire management.

Burning Solid Fuels

Wood Pellets Guidelines

Recommendations for selecting and using wood pellets.

Unpacking and Installation Preparation

Unpacking Your Avent Wood Pellet Stove

Instructions for safely uncrating the stove and inspecting for damage.

Floor Protection Requirements

Specifies required non-combustible floor protection for installation.

Clearances to Combustibles

Details minimum safe distances to walls and other structures.

Exhaust Venting Systems Design

Vent Termination Guidelines

Rules for safe and proper exhaust vent termination points.

Alcove Installation Clearances

Specifies clearances required when installing the stove in an alcove.

Exhaust Venting System Guidelines (Continued)

Clearances to Combustibles

Further details on clearances for venting and appliance.

Exhaust Venting System Precautions

Warnings about flyash, soot, and regular inspection of the venting system.

Exhaust Venting System Design (Continued)

Pipe Length and Altitude Guidelines

Chart and graph to determine appropriate pipe diameter based on length and altitude.

Outside Combustion Air Connection

Required Outside Air Intake

Mandates connection to outside air for combustion on all installations.

Air Intake Termination

Guidelines for terminating the outside air intake pipe, including bend types.

Outside Air Diagram

Outside Air Hookup Diagram

Illustrates the connection point for the outside air intake.

Installation Configurations

Mobile Home Installation Requirements

Specific mandatory requirements for installing the stove in mobile homes.

Alcove Installation Requirements

Specifies dimensions and clearances for alcove installations.

Freestanding Stove Installation

Requirements for freestanding installation, including horizontal exhaust.

Installation Instructions: Conventional & Mobile Home

Vent Pipe Installation Guidelines

General instructions for vent pipe installation, emphasizing manufacturer's guidance.

Glass Maintenance and Replacement

Glass Maintenance and Cleaning

Procedures for cleaning the stove's glass door.

Removal and Replacement of Glass

Step-by-step guide for removing and replacing the stove's glass door.

Stove Controls and Wiring

Cleaning the Glass

Instructions on how to clean the glass surface effectively.

12 Volt DC Wiring Installation

Instructions for connecting a 12V DC battery backup system.

Priming, Lighting, and Operating Instructions

Priming the Auger System

Steps for priming the auger system before initial startup or after fuel depletion.

Starting the Avent Pellet Stove

Detailed procedure for lighting and starting the stove.

Circuit Board Functions

Setting the Draft

Guidance on adjusting draft for optimal combustion and flame.

Maintenance Instructions

Periodic Cleaning and Checks

Schedule and methods for cleaning firepot, heat exchangers, and venting.

Special Cleaning and Operational Instructions

Disposal of Ashes

Proper procedures for safely disposing of stove ashes.

Spring Cleaning

Comprehensive cleaning steps for end-of-season maintenance.

Automatic Safety Features

Power Outage and Overheating Safety

Explains how the stove responds to power loss and overheating.

Auger Cut-Off Safety

Details the function of the auger cut-off and pressure sensor switch.

Thermostat Installation and Options

Thermostat Wiring and Setup

Instructions for connecting and using a wall thermostat for temperature control.

12 Volt DC Wiring Installation

Solar System Connection

Guidance on integrating a solar panel system with the 12V DC battery setup.

Trouble Shooting Guide

Fire Burns Poorly or Soots Up

Identifies causes and solutions for lazy flames and sooted windows.

Trouble Shooting Guide (Continued)

Fire Goes Out or Stove Shuts Down

Addresses issues where the stove extinguishes or shuts down unexpectedly.

Fuel Feed Issues

Troubleshooting steps when the fuel fails to feed properly.

Replacement Parts List

Replacement Parts Identification

Lists part numbers and descriptions for ordering replacements.

Wiring Diagram and Circuit Board Adjustments

Avent Wood Pellet Wiring Diagram

Electrical diagram showing connections for the DCX-5 circuit board.

Circuit Board Fine Tune Feed Adjustment

Instructions for adjusting burn rates via circuit board resistors.

Warranty Information

5 Year Limited Warranty

Outlines the terms and conditions of the manufacturer's limited warranty.

Warranty Exclusions and Limitations

Details what is covered and what is not under the limited warranty.

Service Record

Warranty Claim Submission

Notes that the service record must be sent with warranty claims.