WARNING: These products may represent a possible shock or re hazard if improperly
installed or attached in any way. Products should be installed in accordance with
these instructions, and with current electrical codes and/or the current National
Electric Code (NEC).
Warning: To avoid electric shock, disconnect power prior to installation.
Caution: Injury to persons and damage to the xture and/or mounting surface may
result if the xture is pulled from the surface. To reduce the likelihood of such injury
or damage, mount on a surface that is mechanically sound.
Use only a mild soap and/or water with soft cloth to clean the xture. Harsh chemicals will damage
the xture. Do not wipe the xture with a rough cloth that may scratch the nish or the lens.
Supply wires connection via housing knockouts:
1. Remove the lens cover from the xture by lifting its back edge up gently and rotating it toward
the front of xture. See Figure 1.
2. Punch out whichever knockout is best suited for connection to 120V supply wires. Knockouts
are located along back and top of housing. See Figure 2.
3. Detach cover of wiring compartment by squeezing its front edge and rotating it backward in its
self-hinge. See Figure 3.
4. Install cable connnector and connect xture wires following National Electric Code and/or local
building code requirements. See Figure 4. AC supply should be 120V protected by circuit
breaker or fuse.
5. Use minimum 18AWG solid copper wires. Attach line voltage AC supply wires to xture lead
wires: Black to Black, White to White, Green or bare wire to Yellow/Green (Ground) inside the
xture. Secure each connection using the quick connector provided on the xture lead wire.
See Figure 5.
NOTE: If your system has no ground wire, you should consult a qualied electrician before
proceeding with the installation.
NOTE: Electric shock, overheating, low or no light output and shortened xture life can result if
proper grounding is not done.
6. Replace the wiring compartment cover, securing lip under metal retaining tabs. See Figure 6.
NOTE: Be sure that the wires are not pinched or damaged by any part of the housing or cover.
Mounting xture:
NOTE: Lens cover must be o.
1. Determine desired location of xture and
mark locations of mounting holes (mark at
the small end of each keyhole slot).
2. Use a drill gun (or start holes with an awl)
and screw in mounting screws at these
locations, leaving 1/8” between head of
screw and mounting surface.
3. Slide xture over the mounting screws
using the keyhole slots to hold it in place,
then use a Philips screwdriver or driver bit
to tighten mounting screws and secure
xture to surface.
4. Replace the lens cover by tucking front lip
under front edge and pressing down rmly along
its entire length until it is secure. See Figure 7.
Multiple xtures may be interconnected with linking
cables (3” cable included with xture, other sizes sold
separately). SEE REVERSE FOR CONNECTING MULTIPLE
FIXTURES TOGETHER.
SEE REVERSE FOR PLUG-IN INSTALLATION INSTRUCTIONS.
LED Contrax 120V Under Cabinet Light
Installation Instructions for LUC Series
Figure 1
Figure 2
Figure 3
Figure 5
Figure 4
Cable connector
Knockouts
Figure 6 Figure 7
(
L
)
White wire
(
N
)
Black
wire
Yellow/Green wire
(G)
Keyhole slot
16” unit shown.
See reverse for
other sizes.
PAGE 1 OF 1
RV1637 www.americanlighting.com
© 2016 American Lighting, Inc. Denver, CO 80239
Question and Answer IconNeed help?

Do you have a question about the American Lighting LUC Series and is the answer not in the manual?

American Lighting LUC Series Specifications

General IconGeneral
BrandAmerican Lighting
ModelLUC Series
CategoryLantern
LanguageEnglish

Summary

Supply Wires Connection via Housing Knockouts

Prepare Fixture for Wiring

Remove lens cover, punch out knockout, detach wiring compartment cover.

Connect Fixture Wires

Install cable connector and connect fixture wires (Black to Black, White to White, Ground to Yellow/Green).

Secure Wiring Compartment

Replace wiring compartment cover, ensuring wires are not pinched.

Mounting Fixture

Prepare Mounting Surface

Determine location, mark holes, and screw in mounting screws leaving 1/8" gap.

Attach Fixture to Surface

Slide fixture over mounting screws using keyhole slots and tighten screws.

Replace Lens Cover

Tuck front lip of lens cover under front edge and press down firmly.

Plug-in Installation

Prepare Fixture for Plug-in

Remove lens cover and mount fixture using keyhole slots and screws.

Connect Power Cord

Insert power cord into fixture end port and plug into 120V AC receptacle.

Additional Safety Measures

Handling and Usage Precautions

Avoid looking directly at LEDs, touching LEDs, or operating with a missing lens.

Fire Risk and Location

Keep fixtures away from combustible materials; suitable for indoor dry locations only.

Dimming Compatibility

Product is dimmable; use specified Lutron dimmers for best results (5-100% control).

Connecting Multiple Fixtures

Interconnecting Fixtures

Use linking extensions to connect up to 50 fixtures to one power cord or hardwired fixture.

5-Year Limited Product Warranty

Warranty Coverage

Warrants against defects in material/workmanship for five years; repair or replacement at discretion.

Claim Submission

Claims must be submitted to the retail location; proper documentation required.

Warranty Limitations

Excludes misuse, abuse, consequential damages; applies only to properly installed products.