SAFETY INFORMATION
Read all installation instructions before beginning; if not qualified, do not
attempt installation. Contact a qualified electrician.
To reduce the risk of fire, electric shock, or injury to persons, pay close
attention to this manual and stay within its guidelines when using this
product. Save these instructions for future use.
Do not cover this product as the covering may cause rope to overheat,
melt, or ignite.
Do not operate Trulux® tape light while on the reel, nor while it is coiled.
This IP54 rated tape light is cULus Listed and suitable for indoor use in
dry and damp locations, but not for direct contact with water or moisture.
Do not submerge flexible light in liquids nor use the product in
the vicinity of standing water or other liquids, or where water can
accumulate.
Do not route the cord or tape light through walls, ceilings, doors,
windows, or any similar part of the building structure.
Secure tape light using only the attached adhesive strip.
Do not secure this product or its cord with staples, nails, or like means
that may damage the outer jacket or cord insulation.
Do not use if there is any damage to the tape light, LED diodes, or power
cord insulation; inspect periodically.
Do not install on gates or doors, or where subject to continuous flexing.
Do not install in tanks or enclosures of any kinds.
This kit includes a 24V DC plug-in power supply (3A) that is cULus Listed
for dry location use. Use only the power supply provided. This power
supply allows for a maximum run of 16.4 feet of tape light. Do not exceed
16.4 feet oftape light in any single run.
The RF remote controller included utilizes a 3V CR2025 battery; only
replace with same battery type. Please dispose of batteries properly.
Batteries are not a toy! If swallowed, contact local emergency services
immediatley.
These products may represent a possible shock or fire
hazard if improperly installed or attached in any way.
Products should be installed in accordance with these
instructions, current electrical codes, and/or the current
National Electric Code (NEC).
Use only included 24V DC driver. Factory warranty will
be void if used with a non-recommended power supply,
transformer, or driver.
To reduce the risk of fire, electric shock or injury to
persons, make sure that the electrical power to the
system is disconnected at the source prior to installation
or any servicing.
Never fold Trulux® tape light or bend past the minimum
bending radius of 1” whether lighted or unlighted.
Page 1 of 2©2018 American Lighting, Inc. REV1807 www.AmericanLighting.com 11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
WARNING
WARNING
WARNING
WARNING
TRULUX
®
TUNABLE CCT (IP54) KIT24V
INSTALLATION INSTRUCTIONS
HTL-TW-5MKIT
KIT CONTENTS:
(1) 16.4ft (5m) Reel of Trulux® Tunable CCT IP54 (unjacketed) tape light
(1) Inline LED Controller/Receiver
(1) Tunable CCT Radio Frequency Remote Control
(1) 24V DC Power Supply (3A)
(1) 15ft Reel of 20AWG wire
(3) Tape-to-Tape snap connectors
(6) Tape-to-Wire snap connectors
INSTALLING TRULUX® TAPE LIGHT (See Figure 1):
Make all connections and mount in place prior to providing power to system. Trulux® Tape Light includes a 3M adhesive backing: Allow
adhesive to cure 24 hours prior to rst use. This product is designed to be mounted to a smooth, clean, non-moving surface.
1. Determine the placement of tape light and whether there will be cuts, splices, or jumpers needed. Make any cuts, splices, or
jumps prior to moving on to Step 2. See CUTTING & LINKING TRULUX® TAPE LIGHT KITS on next page for more information on
cutting and/or linking Trulux® Tape Light. Consider the placement of the power supply and ensure there is no tension from start of
tape light to power supply.
2. Peel the protective backing from the tape light and press the Trulux® tape light into place. For best results, once the VHB protective sheet
is removed, the tape should not be repositioned, removed, or re-used.
3. Connect the mating DC plugs from the start of the tape light reel to the LED controller/receiver.
4. Connect the mating DC plugs from the LED controller/receiver to the DC power supply.
5. Plug DC power supply into standard 120V wall socket.
FIGURE 1
24V DC Plug-In Power Supply
LED Controller/Receiver
Trulux Tunable CCT Tape Light
Pre-Attached Connection
To 120V
Question and Answer IconNeed help?

Do you have a question about the American Lighting TRULUX HTL-TW-5MKIT and is the answer not in the manual?

American Lighting TRULUX HTL-TW-5MKIT Specifications

General IconGeneral
TypeLED Tape Light
Length5 meters
Voltage24V DC
IP RatingIP20
CRI90+
LED ChipSMD 5050
Warranty5 years
Color TemperatureTunable White (2700K-6500K)
DimmingYes
Operating Temperature-20°C to 40°C
CuttableYes

Summary

Safety Information

General Safety Warnings

Product installation and use require adherence to safety guidelines to prevent shock, fire, or injury.

Installation Instructions

Installing Trulux Tape Light

Steps for mounting and connecting Trulux tape light, including adhesive curing and power connection.

Cutting and Linking Trulux Tape Light Kits

Making a Tape-to-Tape Connection

Procedure for connecting two pieces of tape light using a snap connector, ensuring polarity alignment.

Making a Tape-to-Wire Connection

Procedure for connecting tape light to wire using a snap connector, maintaining polarity and wire alignment.

RF Remote Controller Usage

Remote Controller Functions

Guide to operating the RF remote controller, including power, reset, color temperature, dimming, and flash modes.

Related product manuals