TROUBLESHOOTING GUIDE
POSSIBLE CAUSE SUGGESTED ACTION
SYMPTOM: Burners do not come on.
Unit is not connected to gas service Visually check unit is plumbed to gas
Pilot is not burning Light pilot
Thermostat is set to very low temperature Set temperature to desired value
SYMPTOM: Fryer does not reach selected temperature.
Unit may not have been operating long enough Unit preheats to 350ºF in about ten minutes
Thermostat may be defective Unit will require service
Too little gas pressure, dirty gas line Call for authorized service
SYMPTOM: General frying problems.
Temperature too low or too high Set unit to recommended temperature for foods being fried.
Thermostat out of calibration Unit will require service
Always disconnect the gas service before cleaning or
servicing the fryer.