Page 9<&(%$*4.8"4,7%H'*#$"&8#I%/7*,#*%4,77%JKLLLKLMMKNOPO1Item 64018
?@<6AQRS6;@ACRED@CEA6E@ET6 ?6AFS
;*#"#$,84*%D*,#'(*5*8$
Measure circuit resistance up to 40M Ohms.
WARNING! To prevent electric shock, turn
off all power and fully discharge capacitors
on the circuit under test before measuring.
1. Turn the Rotary Switch
to the Ω position.
2. Carefully touch exposed
conductors with tips of probes.
3. Read measured resistance
on the Display.
4. When testing is complete, turn Rotary
Switch to R<< and store Meter.
E&$*- Sometimes the resistor value and
measured resistance differ. This is due
to the Meter’s output test current going
through all possible paths between leads.
E&$*- For resistance measurements
above 1MΩ, allow a few seconds
to get a steady reading.
E&$*- When leads are disconnected
or measurement is out of
range, RG is displayed.
T&8$"8'"$>%D*,#'(*5*8$
Test continuity between two
points of a circuit.
WARNING! To prevent electric shock, turn
off all power and fully discharge capacitors
on the circuit under test before measuring.
1. Turn the Rotary Switch to
the % position.
2. Press ?6G6TA until is displayed.
3. Connect the test leads across
the circuit to be measured.
4. Read measured resistance on the
Display. If the measured resistance
is less than 50Ω, Meter will beep.
5. When testing is complete, turn Rotary
Switch to R<< and store Meter.
E&$*- If Test Leads are open or
the resistance of the circuit is out
of range, RG is displayed.
X"&9*%D*,#'(*5*8$
Test voltage drop in diodes.
Open circuit voltage is 1.5V.
WARNING! To prevent electric shock, turn
off all power and fully discharge capacitors
on the circuit under test before measuring.
1. Turn the Rotary Switch to
the % %position.
2. Connect red probe to diode’s anode
and black probe to its cathode.
3. Read measured forward-biased
voltage drop on the Display.
E&$*- If the test leads are reversed
or open, RG is displayed.
4. When testing is complete, turn
Rotary Switch to R<< and store Meter.