EasyManua.ls Logo

AmFor 881 - Test Lead N (B Circuit)

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
00
200200
100100
5050
150150
STARTER
AMPS
STARTER
AMPS
00
22
44
66
88
1010
MILLIAMPERE
METER
MILLIAMPERE
METER
00
3030
1010
2020
ALTERNATOR
VOLTAGE
ALTERNATOR
VOLTAGE
00
3030
1010
2020
ALTERNATOR
AMPS
ALTERNATOR
AMPS
STARTER AMPERAGE
0
STARTER AMPERAGE
0
4
a
m
p
4
a
m
p
BlueBlue
GreenGreen
RedRed
BAD DIODE LIGHT CHARGE LIGHT AUXILIARY LIGHTBAD DIODE LIGHT CHARGE LIGHT AUXILIARY LIGHT
MILLIAMPERE METER
6 or less
MILLIAMPERE METER
6 or less
ALTERNATOR VOLTAGE
13 to 16
ALTERNATOR VOLTAGE
13 to 16
ALTERNATOR AMPERAGE
12 to 16
ALTERNATOR AMPERAGE
12 to 16
offoff
offoff
Test LeadsTest Leads
and
881 Alternator
Starter Test Bench
Red clip
Black clip
Pdc/nwr/inv/881/881-manual/green/889-N-B.cdr
Test Lead N “B” CircuitTest Lead N “B” Circuit
STARTER VOLTAGE
STATOR VOLTAGE
7 to 8
STARTER VOLTAGE
STATOR VOLTAGE
7 to 8
00
3030
1010
2020
STARTER / STATOR
VOLTAGE
STARTER / STATOR
VOLTAGE
offoff
EXTERNALLY REGULATED
Many alternators use the same plug with different wiring. Please
refer to test lead chart for the correct test lead requirements!
1. Readings for a good alternator are in the shaded area. All meter
readings are ±5%..
2. Insert lead as shown below and slide alternator onto alternator
holder pin.
3. Install the belt making sure it is under the belt retaining clip. Slide
the green handle to the right, locking handle into retaining tab and
close the belt guard. Make sure to keep your fingers and clothing
free of the pulley and belt.
4.Turn on motor switch. The charge light on the panel should be lit.
If not, check and reset the circuit breaker on the front panel.
5. Press the GREEN test button. While pressing button, observe
meters for proper readings. Hold for no more than 10 seconds.