TRANSLATION OF THE ITALIAN ORIGINAL INSTRUCTIONS - 29 -
When running, the appliance will cool the cell until the currently set operating
temperature is reached. Once the set operating temperature is reached, the elec-
tronic control unit will turn off the cooling unit until the temperature detected by
the probe rises by about 4-5 degrees. When this happens, the control unit will
turn on the cooling unit to lower the temperature until it returns to the set oper-
ating temperature. This on-off mechanism is perfectly normal and is common
in all refrigeration equipment such as refrigerated bars, cabinets, display cases,
etc. Please note that the temperature shown on the control unit display refers to
the air temperature (very susceptible to temperature changes due to the opening
of the door) and not to the temperature at the core of the appliance, which is
much more constant over time.
Internal light
All models are equipped with internal light. Proceed as follow to turn on or off the light. Models
AKD100W, AKD200W, AKD300W, AKD400W:
Open the door;
Press the switch located in the upper part of the door stop frame.
Model AKD400WZ:
Press the LIGHT button (both with locked or unlocked keyboard).
Error messages displayed on the control unit:
MESSAGE
ERROR DESCRIPTION
SOLUTION
Models AKD100W, AKD200W, AKD300W, AKD400W
P1
Temperature probe defective or
disconnected
Contact the dealer
Model AKD400WZ
1H or 1L
Upper cell temperature probe
defective or disconnected
Contact the dealer
2H or 2L
Lower cell temperature probe
defective or disconnected
Contact the dealer
3H or 3L
Evaporator probe defective
Contact the dealer
HA or Lo
Problems with the upper cell
temperature
Contact the dealer
If one or more error codes are displayed, write them down, turn off the appliance then turn it back
on after 3-4 minutes. If one or more of the codes are again displayed, contact the dealer to request
technical support and inform them of the error codes.
Food storage
The following instructions should be followed in order for the appliance to perform at its best:
Put the food into the appliance after it has reached the desired temperature displayed on the
control unit. To avoid restricting air circulation, do not put too many products in the upper part
of the refrigerator;
Do not place hot foods inside the appliance (they must be previously cooled in a blast chiller)
or in unclosed containers. Always package and protect foods before putting them in the refrig-
erator;
Avoid opening and door frequently and for prolonged periods of time, and wait at least 30
seconds before re-opening the door.