Item: based on the runing target
month or the runing hour to
maintain
each time
the first
month or
20h
every
3month or
50h
every
6month or
IOOh
every I year
or 300h
ENG oil
check the level
o
change
o
Air cleaner filter
check
o
clean
o
Sedimentation glass
clean
Spark plug
check-adjust
replace
Valve clearance
Check -adjust
Combustion chambe
clean
every 500h
Case and filter
clean
Fuel hose
check
every two years(if necessary,please replace)
8.1 Changing the oil: Make sure you warm up the unit for
a short period of time to ensure all oil residues will drain.
8.1 .1 Make sure the unit is off of the ground to leave
enough space to drain the oil into a container. Remove
the oil plug, oil bolt and the seal.
8.1 .2 Make sure the oil is drained completely. Then
tighten the bolt and replace the seal. To purchase a new
seal please contact AMP Industrial.
8.1 .3 Fill the unit with oil into the crankcase to the
recommended level on the oil dipstick plug. Once you