All specifications are subject to change. Please contact MTS for specifications that are critical
to your needs. For additional information go to www.mtssensors.com.
Temposonics
®
Magnetostrictive Position Sensors
G-Series Linear Position Sensor
Analog and Digital Pulse Outputs
User’s Manual
Connection Options
Temposonics Model GP
Temposonics Model GH
1
2
3
4
5
6
1
23579
46810
A
B
C
DE
F
G
H
JK
O
O
p
p
t
t
i
i
o
o
n
n
D
D
6
6
0
0
O
O
p
p
t
t
i
i
o
o
n
n
R
R
B
B
_
_
O
O
p
p
t
t
i
i
o
o
n
n
F
F
M
M
_
_
Temposonics G-Series sensors are preconfigured at the factory by model
code designation. If needed, a variety of retrofit and replacement options are
available to provide direct backwards compatibility for your application.
G
G
-
-
S
S
e
e
r
r
i
i
e
e
s
s
s
s
e
e
n
n
s
s
o
o
r
r
c
c
o
o
n
n
n
n
e
e
c
c
t
t
i
i
o
o
n
n
o
o
p
p
t
t
i
i
o
o
n
n
s
s
:
:
Integral 6-pin DIN male connector, (option “D60”)
Integral cable with pigtail end, standard type (option “R _ _” ), and
heavy duty type (option “F _ _” )
Integral cable with in-line RB type male connector (option “RB _” )
Integral cable with in-line MS type male connector (option “FM _” )
Depending on the sensor output selected (Analog, Digital Pulse, or Neuter )
the different wiring required for the applicable combinations are shown in
Tables 1-3. Pin-outs for the above connector types are illustrated in Figure 1.
Figure 1 - G-Series Connector Pin-Outs
N
N
o
o
t
t
e
e
s
s
:
:
These notices provide important tips, guidance or advice.
I
I
m
m
p
p
o
o
r
r
t
t
a
a
n
n
t
t
:
:
These notices provide information that might help you avoid inconvenient or problem
situations.
C
C
a
a
u
u
t
t
i
i
o
o
n
n
:
:
These notices indicate situations that can be potentially hazardous to you. A caution
notice is placed just before a description of a potentially hazardous procedure, step or
situation.
Notices used in this user’s manual
In-line MS connector
In-line RB connector
Integral Connector (D6 Male)
(As viewed from end of sensor)

Other manuals for Amphenol Temposonics G Series

Question and Answer IconNeed help?

Do you have a question about the Amphenol Temposonics G Series and is the answer not in the manual?

Summary

G-Series Connector Pin-Outs

Integral Connector D6 Male

Pin-out diagram for the D6 male integral connector.

In-line RB Connector

Pin-out diagram for the RB in-line connector.

In-line MS Connector

Pin-out diagram for the MS in-line connector.

G-Series Connection Options

Available G-Series Sensor Connections

Details factory preconfigured and retrofit connection options.

G-Series Wiring and Connections

Analog Output Connections

Wiring and pin-out details for analog output connections.

Digital Pulse Output Connections

Wiring and pin-out details for digital pulse output connections.

Square Wave Neuter Output Connections

Wiring details for backward compatibility with older sensors.

G-Series LED Diagnostic Codes

G-Series LED Code Table

Table detailing LED indicators for sensor status, errors, and programming modes.

G-Series External Programming and Diagnostics

G-Series Programming and Diagnostic Tools

Overview of tools for sensor configuration and diagnostics.

G-Series PC Setup Software Overview

PC Setup Software Equipment and Hardware Setup

Lists required equipment and hardware connection notes.

Establishing PC Serial Communication

PC Serial Communication Setup Steps

Step-by-step guide to establish serial communication via PC.

PDA Programming and Diagnostics

PDA Programming Equipment and Hardware Setup

Lists necessary equipment and hardware setup for PDA programming.

Establishing PDA Communications

PDA Communication Setup Steps

Guide on establishing IR communication between PDA and sensor.

PDA Sensor Parameter Operations

Reading Sensor Parameters via PDA

Instructions on how to read sensor parameters using PDA software.

PDA Magnet Position Reading

Reading Magnet Position via PDA

How to display and read magnet position in mm via PDA.

PDA Sensor Set Programming Mode

Set Mode Programming Operations

Steps to enter set mode and modify digital pulse output parameters.

Analog Setpoint Programming with IR Programmer

IR Programmer Equipment and Setup

Lists equipment and setup for analog setpoint programming via IR.

Analog Setpoint Adjustment Procedure

Null and Span Adjustment Steps

Steps to adjust Null (Setpoint 1) and Span (Setpoint 2) using IR programmer.

Appendix A: G-Series Sensor Parameter Definitions

G-Series Sensor Parameter Glossary

Glossary defining various parameters related to G-Series sensors.

Appendix A: G-Series LED Diagnostic Code Definitions

G-Series LED Diagnostic Code Glossary

Explains the meaning of G-Series sensor LED diagnostic codes.

Amphenol Temposonics G Series Specifications

General IconGeneral
SeriesG Series
TechnologyMagnetostrictive
Product TypeLinear Position Sensor
ManufacturerAmphenol
Output TypeAnalog, Digital
Repeatability±0.001% of full scale
Operating Temperature-40°C to +85°C
Housing MaterialStainless Steel
Protection RatingIP67