EasyManua.ls Logo

AMS Neve CAPRICORN - User Manual

AMS Neve CAPRICORN
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2003 AMS Neve plc own the copyright of all
information and drawings contained in this manual which
are not to be copied or reproduced by any means or
disclosed in part or whole to any third party without
written permission.
As part of our policy of continual product improvement,
we reserve the right to alter specifications without notice
but with due regard to all current legislation.
Disclaimer: The information in this manual has been
carefully checked and is believed to be accurate at the
time of publication. However, no responsibilty is taken by
us for inaccuracies, errors or omissions nor any liability
assumed for any loss or damage resulting either directly or
indirectly from use of the information contained within it.
AMS NEVE INC., NEW YORK
TEL: +1 (212) 965 1400 FAX: +1 (212) 965 9306
AMS NEVE INC., HOLLYWOOD
TEL: +1 (818) 753 8789 FAX: +1 (818) 623 4839
AMS NEVE PLC BILLINGTON ROAD BURNLEY
LANCS BB11 5UB ENGLAND
TELEPHONE: +44 (0) 1282 457011 FAX: +44 (0) 1282 417282
HEAD OFFICE
TELEPHONE: +44 (0) 20 7916 2828 FAX: +44 (0) 20 7916 2827
LONDON OFFICE
NORTH AMERICAN OFFICES
e-mail: enquiry@ams-neve.com
http://www.ams-neve.com
USER MANUAL
527-140
Issue 5.1
CAPRICORN

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AMS Neve CAPRICORN and is the answer not in the manual?

Summary

Introduction

Overview

Provides a general overview of the Capricorn recording system and its features, including its innovative audio technology.

Concepts of Allocating Processing

Explains how the digital console uses software-controlled processing power for signal paths and elements like EQ, compressor, and filter.

The Console Surface

Details the three types of sections on the Capricorn console surface: Strip Sections, Monitor Section, and AFU Section.

The Graphics Display

Describes the high resolution color graphics screen, trackball, and keyboard as primary tools for graphical interface and complex functions.

Getting Started

Using the Trackball with the Graphics Display

Explains how the trackball controls the screen pointer for selection, modification, and interaction with graphics.

Logging on to the system

Recommends logging on to the desk to store personal configurations, protected by a password.

Using the Soft Panel Menus

Describes the Soft Panel, its vacuum fluorescent display, and twelve programmable keys for function control.

Bank Assignments

Explains Capricorn's twelve sets of signal path to channel strip assignments, called banks, selected via the Graphics Display.

Using Console Surface Controls

Details the console surface controls, including double action keys and touch-sensitive rotary controls.

Using the AFU

Explains the Assignable Facilities Unit (AFU) containing individual controls for auxiliaries, equalization, and routing.

Further Information

Guides the user to relevant chapters for setup, configuration, and basic operation information.

Console Setup

Introduction

Explains console setup using the Graphics Display screen for various operations like recording, mixdown, and broadcast.

Configuration Management

Describes the Configuration Record/Recall screen for managing configurations stored under the logged-on user ID.

Backup and Restore

Explains transferring data to and from removable disks for system backup and archiving.

Path Numbers

Details the six different types of paths and how their numbers determine the console setup in the current configuration.

Path Configuration

Naming a Path

Explains how a Path assigned to a Channel Strip can be given a four-character user name shown in the alpha display.

Assigning a Path to new Fader

Describes an alternative method of assigning a path to a fader on a different bank via the Path Configuration Screen.

Processing Configuration

Details how processing elements are placed in order within a signal path, pre or post fader.

Signal Matrix

Explains the Signal Matrix facility for triggering relays by fader actions, useful for starting external devices.

Input;Output Configuration

Ports and Paths

Explains that all input/output paths need connection to digital or analogue input/output Ports.

To Assign Ports to Paths

Guides on assigning ports to paths for input, output, and track return paths using the Path Configuration screen.

Inserts

Details how Capricorn provides 32 Inserts, placeable anywhere on a signal path, connectable to analogue or digital ports.

Multitrack Tape Machine Interconnection

Describes connecting multitrack tape machines via Track send outputs and Track return inputs using software routing.

Miscellaneous Setup

Sample Frequency

Allows setting the Wordclock Synchronisation rate and source, automatically storing the last value set.

Desk Level

Adjusts input and output operating levels via a hybrid switched gain amplifier before signals pass through ADCs or DACs.

Delay Times

Allows setting delay periods for various functions like help display, double-click, keyboard dwell, and repeat periods.

Intensity

Allows adjustment of control and display brightness on the console surface, from 1 (dimmest) to 15 (brightest).

Routing

Routing

Describes internal signal routing control via dedicated keys on the Assignable Facilities Unit and AFU.

Interrogation

Explains forward and reverse interrogation to see destinations or paths routed to a specific point.

Other Routing Panel Functions

Covers Film Mode, Stem Sel, MS, and Dual Mono functions for routing and signal definition.

Monitoring

Monitoring Controls

Details strip monitor mode controls, global monitor mode controls, and SLS/Phones settings.

Control Room Monitoring

Explains controlling the main monitoring system, selecting loudspeakers, and modifying signal sent to speakers.

SLS and Headphone Monitoring

Covers source selection for studio loudspeakers and headphones, including follow monitor and cut functions.

Overdub Monitoring

Provides comprehensive controls for monitoring during overdub or mixdown sessions, including cue monitoring.

Metering

Meter Scale

Explains system metering characteristics, scale options (dBFS/dBu), and offset settings.

Overload

Details overload indicators on meters, including signal path and input meters, and their behavior.

Meter Operation

Describes meter modes like Hi-Res and Assignable Meter modes, including Peak, Peak Hold, and VU/Phase metering.

Channel strip Meter Mode Selection

Explains how to select meter modes for channel strips using the Meter Select panel.

Signal Processing

Using Channel Strip Banks

Explains how 12 Banks define path-to-strip assignments, allowing different layouts and easy control access.

Function Indicators

Details function indicators on strips showing assigned processing elements and their on/off status.

Input Paths

Describes input paths for microphones and line sources, fed from Mic/Line or Digital I/O racks.

Monitor Signal Paths

Explains monitor paths' different functions from input paths, receiving signals from multitrack tape machines.

Auxiliaries and Cues

Aux Control

Details how auxiliary paths can be configured with EQ, filters, and other inserts, and assigned to banks.

Contribution Control

Explains adjusting contribution from current path to auxiliaries using Auxiliary/Panning controls.

Aux Flip

Describes the Aux Flip function allowing faders to control Aux contribution levels, with pre/post fader pick-off.

Cue Sends

Covers controlling cue outputs from the Cue Control panel or assigning them to strips, with filters, EQ, and inserts.

Links and VCA Ganging

Control Links

Explains linking controls across paths for proportional effect, allowing up to 256 links of a single control type.

VCA Control

Describes VCA Groups allowing one fader/mute to modify others, with Masters and Slaves, up to 16 VCA Groups.

Editing Links

Details how to edit links, including selecting paths, toggling members, and deleting links.

Out-of-range Offsets

Explains how controls can move beyond physical end-stops, maintaining positions, with offsets handled on touch.

Oscillator

Tone oscillator

Details the tone oscillator controlled via Monitor Section, with variable level/frequency, and routing setup.

Slate Oscillator

Describes the slate oscillator with fixed low level tone for recording onto analogue tape, routable to all track sends.

Talkback

Talkback Setup

Explains setting up talkback switching, routing talkback to track sends, outputs, cues, and speakers.

Talkback Group Levels

Details how to set the level for each Talkback Group independently using the Monitor section levels panel.

Transport Control

Machine Control

Describes controlling machine groups using two sets of transport keys, including machine selection and extra function keys.

Track Control

Explains addressing track ready and record enable controls independently for up to three multitrack machines.

Timecode

Covers Timecode Configuration for matching internal handling to source timecode, including Type of Code and Frame Rate.

Labels

Explains using labels for identifying points in a program, important for locate operations and timecode specification.

Automation Overview

Introduction

Provides an overview of Capricorn's dynamic automation on controls and switch functions, including touch sensitivity.

Automation Controls

Details how the automation system is controlled via keys, including path automation controls and global automation controls.

Scope

Explains how to reduce the scope of the automation system to specific controls, paths, or lists.

Automation Modes

Describes automation modes like Touch Record, Record, Play, Play Safe, Isolate, Auto Glide, and Manual Glide.

Automation Operations

Automation Quick Start

Provides steps for making a first Mix/Pass, including setting console setup and automation scope.

Automation Data

Explains how automation data is stored in a Mix Tree, and how to use Titles for working with automation.

Scope

Details how to set Scope for controls or paths to define automation recognition and display.

Managing Mixes and Passes

Explains the Mix Tree structure, Mix/Pass numbers, Initial Snapshot, and managing mixes and passes.

Offline Editing

Offline Trim

Enables trimming of pre-selected faders for Mix extent or timecode points, monitored in real time or executed offline.

Offline Delete

Allows deletion of dynamic moves or switch actions between nominated timecode points, erasing recorded values.

Mix Conform

Allows automation system to follow changes in production running order, adjusting automation event timecodes.

Slide

Adjusts Timecodes for an entire Mix/Pass by a selected amount, useful for post-production material placement.

Stores

The Store List

Describes how to access and manage the Store List, including reducing list size and scrolling.

New and Set Store Scope

Explains selecting controls for snapshot creation (New Store Scope) and recall (Set Store Scope).

To create a Store

Details the process of creating a new Store, assigning a unique number and optional name.

To delete a Store

Describes how to delete one or multiple Stores from the Store List and confirm the action.

Capricorn Surround

Standard Surround Features

Covers console's surround panning to track sets (Film Groups) with available formats and software upgrades.

CXS

Details the CXS console section for surround monitoring, Film Stem configuration, and meter bridge.

Joystick Module

Explains the Joystick Module for intuitive surround panning control of up to two paths, compatible with CXS or CSP.

Capricorn Surround Panel (CSP)

Describes the CSP option altering transport panel functionality for surround monitoring facilities.

MIDI

MIDI Program Changes

Explains how Capricorn issues MIDI Program changes via a serial port on the AFU assembly.

MIDI Automation

Details how PLAY and REC keys on the MIDI Instruction List automate MIDI number keys.

Diagnostics

DSP

Shows DSP functionality, digital signal processing cards, and allows marking bad elements for ignoring.

Logs

Provides access to a list of errors that have occurred, including Activity Log and the ability to toggle between text and data.

IO Reset

Forces a reset to the rack configuration for MADI ports, affecting the next User Configuration or Automation Title load.

Diags

Accesses miscellaneous system maintenance options via the Diags button, including Logs and Stop System.

AMS Neve CAPRICORN Specifications

General IconGeneral
TypeDigital Mixing Console
EQ4-band parametric EQ per channel
Sampling Rate48 kHz
Bit Depth24-bit
FadersMotorized faders
RecallTotal Recall
DynamicsCompressor/Limiter, Gate/Expander per channel
AutomationComprehensive dynamic automation
Aux SendsMultiple aux sends per channel