Do you have a question about the AMS 700 LGX and is the answer not in the manual?
Model | AMS 700 LGX |
---|---|
Manufacturer | Boston Scientific |
Material | Silicone |
Device Type | Penile Prosthesis |
Configuration | 3-piece inflatable |
Inflation Mechanism | Manual pump |
Reservoir Volume | 65 cc |
Pump Mechanism | Momentary squeeze pump |
Provides a general description of the AMS 700 Penile Prosthesis product line and its components.
Details the components of each cylinder kit, including materials and protective sleeves.
Describes the components of the MS pump, including the bulb, deflation button, and tubing.
Outlines the reservoir components, including fluid storage and tubing connections.
Specifies the configurations and features of the AMS 700 CX model.
Details the configurations and features of the AMS 700 LGX model.
Describes the configurations and features of the AMS 700 CXR model.
Provides guidelines on the sterilization of AMS 700 components.
Lists and describes the surgical instruments available for implantation.
Details proper storage conditions for AMS 700 components.
Lists instruments and sterile supplies required before surgery.
Identifies specific needles used for filling and flushing procedures.
Describes tubing used to protect hemostat tips from tubing damage.
Lists various connectors and accessories for tubing assembly.
Details necessary documentation for the implant procedure.
Describes the proximal tool used for cylinder insertion.
Instructions for unpacking and preparing surgical equipment.
Steps for preparing the patient before the surgical procedure.
Overview of infrapubic and penoscrotal surgical approaches.
Guidance on making incisions and dissecting tissue for implantation.
Procedure for dilating and measuring the corpora for sizing.
Methods for selecting the appropriate cylinder size and rear tip extenders.
Instructions for safely unpacking sterile prosthesis components.
Specific procedures for opening and preparing devices with InhibiZone treatment.
General guidelines for preparing all AMS 700 components with saline.
Steps to prepare the non-connected MS pump for implantation.
Procedure for preparing preconnected pump and cylinder assemblies.
Instructions for preparing individual, non-connected cylinders.
Steps for preparing the fluid reservoir before implantation.
Detailed steps for inserting the cylinders into the corpora cavernosa.
Guidance on creating pockets and implanting the reservoir.
Procedure for filling the reservoir with sterile normal saline.
Steps for creating a scrotal pocket and implanting the pump.
Procedure for performing the initial inflate/deflate test.
Steps to perform a test on the pump and cylinders before connecting the reservoir.
Instructions for connecting the main components of the prosthesis.
Methods for connecting tubing using various connector types.
Detailed procedure for using AMS Quick Connect Sutureless Window Connectors.
Instructions for making connections using AMS Suture-Tie Connectors.
Procedure for the final inflate/deflate test before closing.
Guidance for care immediately following surgery.
Instructions for patients after release from the hospital.
Procedures for evaluating the device's function over time.
Guidelines for combining different AMS 700 components for specific needs.
Solutions for common problems encountered with cylinders.
Solutions for common problems encountered with reservoirs.
Solutions for common problems encountered with the pump.
Details the antibiotic surface treatment and its benefits.
Explains the parylene coating and its purpose.
Summarizes the intended use and potential adverse events of the prosthesis.