Advises on authorized operators, fluid levels, sensitive parts, and environmental conditions for safe use.
Emphasizes not using during engine running, wearing protective glasses, and testing in draft-free areas.
Connects the unit to the automobile battery for power supply.
Introduces smoke into the system or vacuum pipe for leak detection.
Assists in smoke oil refill, preventing spills onto the unit's surface.
Seals intake and exhaust openings to introduce smoke, useful for non-round shapes.
A replaceable rubber part for the Intake Bladder if it becomes damaged.
Seals intake and exhaust, introduces smoke; may need manual support at high pressure.
Port for refilling smoke oil, with a funnel to prevent surface spillage.
Used for collecting the smoke delivery hose and power cord for storage.
The point where the smoke delivery hose is connected to the unit.
Receptacle for connecting the power cord to the unit.
LED indicators and a switch to manage pressurized air production.
LED indicators and a switch to manage smoke generation and monitor overheat.
Displays the smoke oil level, requiring periodic checks and refills.
This document describes the ANCEL Automotive Diagnostic Leak Detector, a specialized tool designed for identifying leaks in various automotive systems. The device operates by generating smoke, which is then introduced into the system under test, allowing technicians to visually locate leaks as the smoke escapes.
The ANCEL Automotive Diagnostic Leak Detector is primarily used for diagnosing leaks in automotive systems. Its core function involves producing pressurized smoke and delivering it into a sealed system. By observing where the smoke exits, technicians can pinpoint the exact location of leaks that might otherwise be difficult to detect. This method is particularly effective for systems that are not easily accessible or where leaks are too small to be found by conventional means. The device is designed to be compatible with mineral oil-based baby oil, such as Johnson&Johnson Pink bottle, with Pure #5 white oil being the preferred choice for smoke generation.
The unit features a main body that houses the smoke generation mechanism, control switches, and an oil level gauge. It connects to a 12V automobile battery for power, making it portable and suitable for on-site diagnostics. The smoke delivery hose is crucial for channeling the smoke from the unit to the system being tested, often via an adapter cone or a universal intake bladder.
Operating the ANCEL leak detector involves a series of steps to ensure accurate and safe diagnosis. Before starting, it is crucial to turn off the vehicle's ignition, as leak tests require the engine to be off. The air filter and throttle connections should be dismantled, and the inner wall of the intake opening cleaned to prevent damage to the adapter.
The device offers two primary methods for introducing smoke into the system: the Universal Intake Bladder and the Adapter Cone. The Intake Bladder is particularly useful for sealing intake and exhaust systems, especially when the inlet position is not rounded-shape. To use the bladder, it is inserted into the intake opening, and then inflated using a hand pump until the opening is tightly sealed. Once sealed, the smoke nozzle is plugged into the bladder's tube opening to introduce smoke. After testing, the inflated air is released by opening the pressure relief valve.
The Adapter Cone serves a similar purpose, fitting into intake and exhaust systems to seal them and introduce smoke. However, it may require manual support during operation, especially under high pressure, to prevent it from falling out.
The unit's operation is controlled via several switches and indicators. The "Air Control switch" activates the pressurized air production, indicated by a GREEN LED. The "Smoke Control switch" initiates smoke generation, also indicated by a GREEN LED. If the smoke generating chamber overheats, the smoke generation is halted, and the LED turns RED, resuming once the chamber cools down or manually reset.
For optimal leak detection, it is recommended to perform tests in a draft-free area. A bright halogen lamp or working lamp is highly beneficial for enhancing the visibility of the smoke exiting the leak, making it easier to pinpoint the source. After initiating air and smoke generation, a waiting period of approximately 30 seconds allows the system to pressurize, and the unit is ready for leak checks within 2 minutes.
Proper maintenance ensures the longevity and reliable performance of the ANCEL leak detector. A critical maintenance feature is the oil refill port, which allows for easy replenishment of smoke oil. The included funnel assists in pouring oil into the unit, preventing spills onto the device's surface. It is essential to monitor the oil level periodically using the oil level gauge; if the level drops below the MIN line, a refill is necessary, but care must be taken not to exceed the MAX line.
The Intake Bladder Replacement Rubber is a thoughtful maintenance feature. The rubber component of the intake bladder can wear out or break with improper use. Instead of replacing the entire intake bladder, the rubber component can be replaced separately, reducing costs and waste. After each test, it is important to clean the adapter for storage and avoid contact with corrosive liquids to maintain its integrity.
For storage, the smoke delivery hose and power cord can be neatly collected using the integrated Velcro straps. The unit should be stored in an upright position and never laid down to prevent potential damage or leakage. Regular checks of the fluid level before each use are crucial; if the fluid level is low, it must be refilled to the bottom of the filler port. It is also advised not to use the unit on smoke-sensitive parts, such as lamp housings, and to avoid windy environments, which can disperse the smoke and hinder detection. Wearing protection glasses during operation is also a recommended safety practice.
| Display | 7-inch LCD touchscreen |
|---|---|
| RAM | 2 GB |
| Operating System | Android |
| Processor | Quad-core |
| Connectivity | Wi-Fi, Bluetooth |
| Supported Protocols | CAN |
| Languages | English, French, Spanish, German, Italian, Portuguese |
| Power Supply | DC 12V |
| Storage Environment | -20°C to 60°C |