Pipette Accuracy Tester
PT-Series
AD-4212B-PT
A
D-4212A-PT
F
X-300i-PT
INSTRUCTION MANUAL
1WMPD4001794A
Question and Answer IconNeed help?

Do you have a question about the AND PT Series and is the answer not in the manual?

AND PT Series Specifications

General IconGeneral
BrandAND
ModelPT Series
CategoryTest Equipment
LanguageEnglish

Summary

Introduction to Pipette Accuracy Tester

Unpacking the Pipette Accuracy Tester

Instructions for safely unpacking the pipette accuracy tester and its components from the carrying case.

Description of Each Component

Detailed overview of all parts included with the pipette accuracy tester, explaining their function.

WinCT-Pipette Software for Accuracy Testing

Explanation of the WinCT-Pipette software features for analyzing pipette accuracy test data.

Function of the Evaporation Trap

Details on how the evaporation trap prevents evaporation of test liquid and acts as a breeze break.

Sample Cup Description

Information on the sample cup's design and the water-absorbent sheet for accurate measurements.

Assembling the Pipette Accuracy Tester

Assembly for AD-4212B-PT / AD-4212A-PT

Step-by-step guide for assembling the AD-4212B-PT and AD-4212A-PT models.

Assembly for FX-300i-PT

Step-by-step guide for assembling the FX-300i-PT model.

Precautions Before Use

Anti-Static Treatment

Installing WinCT-Pipette Software

Connecting a PC to the Balance

Connecting a PC via COM or USB Port

Instructions on establishing PC connectivity using RS-232C or USB converter.

Checking COM Port Numbers

Procedure to identify and verify COM port numbers using Windows Device Manager.

Calibrating the Balance

Calibration Procedure for AD-4212B-PT / AD-4212A-PT

Step-by-step guide for calibrating the AD-4212B-PT and AD-4212A-PT models.

Calibration Procedure for FX-300i-PT

Step-by-step guide for calibrating the FX-300i-PT model.

Preparation Before Use

Filling the Evaporation Trap with Water

Instructions on correctly filling the evaporation trap with water to maintain humidity.

Preparing the Test Liquid

Guidance on preparing the distilled water and using the thermometer for temperature stabilization.

Preparing the Water-absorbent Sheet

Steps to moisten the water-absorbent sheets for sample cups before testing.

Using the Thermometer

Instructions on operating the thermometer, including battery replacement and display modes.

Measurement Procedures and Error Analysis

Pipette Measuring Procedure

Recommended procedure for performing pipette accuracy measurements according to ISO 8655.

Judging Measurement Results

Criteria and methods for judging pass/fail results based on accuracy and repeatability.

Causes of Measurement Errors

Identification of common causes of errors like evaporation, temperature, and vibration.

AD-4212B-PT / AD-4212A-PT Specific Features

Factory Settings Overview

Details on the default factory settings for the AD-4212B-PT / AD-4212A-PT models.

Display Lock Function Usage

Explanation of how to use the display lock function to compensate for evaporation errors.

Auto Print Mode Functionality

Description of the auto print mode for automatic data transmission to WinCT-Pipette.

Troubleshooting Common Issues

Product Specifications

Available Options and Accessories

List of optional accessories and components available for purchase for the testers.

Appendix