-5-
Action description:
Startup: the fan is turned on, and the compressor 1 is turned on with a delay
of several seconds.
Shutdown: the compressor is stopped immediately, and the fan is stopped
after a delay of several seconds.
Without turning on the power supply, the compressor can be turned on
again after it stops running for 3 minutes.
Defrosting function:
When operating at low ambient temperature, the system will automatically
judge whether there is frost, and if there is frost, it will automatically defrost.
Defrosting action: the fan does not stop and the compressor stops.
End of defrosting: the defrosting indicator is off, and the fan and compressor
operate according to the humidity control requirements.
Defrost display: when defrosting, the defrosting indicator is on.
S/N
Fault code Fault name
1
The display board communication is abnormal
(Ec)
Fault Code
(Whether the above fault codes exist depends on whether the actual
model has this function.)
Notice:
1. In case of Ec fault, the machine operation is not controlled by the
operation panel.