6.0 REPLACEMENT PARTS & TUBING
7.0 TROUBLESHOOTING
Visit our website for factory authorized tubing, pump head components and accessories. Interact
with the icons below to learn more.
Click for
Replacement Parts
Click for
Pump Tubing
Click to visit
ankoproducts.com
Problem Potential Cause Solution
Fluid Leaking
Pump tubing worn Replace tubing
Excessive back pressure
Ensure system pressure does not
exceed tube pressure rating
Tube connection are not tight
Ensure tubing connection are properly
connected
Pump Will Not Start
Outlet is not powered
Verify that the unit is plugged into
functioning outlet
DC Jack has a loose connection
Verify the power cord is rmly
attached to the DC receptacle
Gearbox assembly is worn Replace unit
Pump Runs but Does Not Meet
Rated Flow
Tubing is worn Replace tubing
Non-compatible tubing used Use specied tubing
Fluid viscosity is too high Lower viscosity, use larger bore tubing
Pump height is too high Reduce pumping height
Shortened Tube Life
Non-compatible tubing used Use specied tubing
Seized rollers caused abrasion on tube Clean roller assembly or replace
Fluid is not compatible with tubing Use chemically compatible tubing
Unit is ON but Pump Will Not Turn
Non-compatible tubing used Use specied tubing
Gearbox assembly worn Replace unit