ForRollerReplacement
(Aplasticrollerbracketassemblyissuppliedwithunitsrangingfrom2to108RPM.Noassemblyisrequiredforthe
plasticbracket.Ifnewrollersarerequiredanewassemblymustbeordered).
1. Toremovetherollerbracketassemblyfromthepump,useaflatheadscrewdriverand
pryopenbothsidesofthespringstotheedgeofthebracket.
2. Pulltherollerbracketassemblyofftheshaftholdingontotherollerareaofthebracket.
3. Holdingthetopandbottomofthebracket,slidethespringofftothesideandlaythe
assemblyonaflatsurface.Trynottoletitfallapartasyouwillneedtoputittogether
thesamewayitisnow.
4. Removethetopbracketandtherollers.
5.
Ifarollerpincomesoutofitsrecess,replaceitatthistime.
6. Placethenewrollersonthepinsandreplacethetopbracket.Besurethattheflatinthe
innerholeofthetopbracketlinesupwiththeflatonthebottombracket.
7. Slidethespringfastenerbackoverthebracket.Donotsnapthespringtogether.
8. Matchingtherollerbracketflattotheoutputshaftflat,slidetherollerbracketassembly
downuntilitstopswithoutusingforce.
9. Snapthespringtogether.
Illustrationofthepumpassembly.
