Page #6 background image
a convenient mains socket. If no battery is connected the green LED for
24 V will light. After connecting the battery, the charger switches auto-
matically to the right voltage and the charging procedure will start. The
red LED indicates charging. After charging the red charging LED swit-
ches off and the battery is provided with trickle charging. The battery is
now fully charged and ready for use.
WARNING
When charging lead acid cells, explosive gases can develop. Avoid open
fire and sparks.
TIP
Do not carry out any cleaning if the charger is plugged in. Only use a dry
cloth to clean the charger. Do not use the charger if the housing is da-
maged. Chargers that require repair must be sent to authorised service
agents or dealers.
CAUTION
Keep your charger in a dry place (indoor use only). Never try to open the
charger. Danger of fire and electric shock!
SPECIFICATION
Voltage of the battery End of charging voltage Charging current
2 Volt 2.3 V 900 mA
6 Volt 6.9 V 700 mA
12 Volt 13.8 V 600 mA
24 Volt 27.6 V 300 mA
Deutsch | English | Français | Pусский | Español | Português
Svenska | Italiano | Nederlands | Dansk | Slovenščina
Čeština | Slovenský | Polski

Other manuals for ANSMANN ALCS 2-24 A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ANSMANN ALCS 2-24 A and is the answer not in the manual?

ANSMANN ALCS 2-24 A Specifications

General IconGeneral
BrandANSMANN
ModelALCS 2-24 A
CategoryBattery Charger
LanguageEnglish

Related product manuals