EasyManuals Logo
Home>AODE MACHINERY>Temperature Controller>AWM-05A

AODE MACHINERY AWM-05A User Manual

AODE MACHINERY AWM-05A
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
Aode Machinery Co., Ltd Page 17 of 26
奥德机械有限公司 2012
7.1.2 电路板内部参数设定:(Internal circuit boards to set parameters)
①. 回油温度误差设定:
Return oil temperature setting error
按住电源开/ 5 秒,进入回水温度误差间设定界面。“回水温度”显示处出现的数字
就是回水温度误差。
Hold down the power on/off switch 5 seconds. Enter the setting interface of return water
temperature error. The displaying figure on the return water is the returning water temp. error.
/关机按扭会使回水温度(回油温度上数字)减少;
Press the start/off button, the figure of the return water temp. will decrease.
/复位按扭会使回水温度(回油温度上数字)增加。
Press the alarm/reset button, the figure of the return water temp. will increase.
②. 开机冷却工作时间设定:
Cooling time to start working to set
按住电源开/关键 5 秒,进入回油温度误差间设定界面,按一下电源开/后进入开机冷却时
间设定界面,在“回油温度显示处出现的数字就是开机冷却工作时间,单位为秒。
Hold down the power on/off switch 5 seconds, enter the return water temp. error setting interface,
Click the power on/off after boot time to set the cooling interface Return water temperature in
the show appeared that the number of working hours start to cool, for the second unit.
/关机按扭会使开机冷却时间(回水温度上数字)减少;
Press the start/off button, the starting up cooling time (the figure of the return water temperature)
will be reduced.
/复位按扭会使开机冷却时间(回水温度上数字)增加。
Press the alarm/reset button, the starting up cooling time (the figure of the return water
temperature) will be increased.
③. 报警延时输出时间设定:
Time setting of alarm delay output
按住电源开/关键 5 秒,进入回水温度误差间设定界面,按一下电源开/后进入开机冷却时
间设定界面,再按三下电源开/后进入报警延时时间设定界面。在“回水温度显示处出
现的数字就是报警延时时间,单位为秒。
Press the power on/off switch key for 5secs, enter the return water temp. error setting interface,
press the power on/off switch key, enter the starting cooling time setting interface, press the
power on/off switch key for three times , enter the alarm delay time setting interface which is the
figures displayed on the return water temp. screen, and its unit is sec.
④. 在按电源开/就退出内部参数设定进入正常工作状态。
Press the power on/off again and enter into the normal working
注:AWM-05A/10A 型机无此功能
Note: AWM-05A/10A model is without this function;

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AODE MACHINERY AWM-05A and is the answer not in the manual?

AODE MACHINERY AWM-05A Specifications

General IconGeneral
BrandAODE MACHINERY
ModelAWM-05A
CategoryTemperature Controller
LanguageEnglish