Product Introduction

Multifunction Process Calibrator

Overview of the CALYS 50/75/100 multifunction process calibrator.

Software Overview

Safety Instructions

Safety Standards and Operation

Details compliance with EN 61010-1 and safe unit operation guidelines.

Getting Started

Powering On and Basic Measurement

Procedure for initial power-up and basic measurement operations.

Measuring DC Voltage and Current

Step-by-step guides for measuring DC voltage and current.

Temperature and Pressure Measurement

Guides for measuring temperature and pressure.

Generation; Simulation

DC Voltage and Current Generation

Steps to generate DC voltage and current outputs.

Advanced Operation

Simulation Modes Overview

Introduces various transmission modes for checking instruments and transmitters.

Calibrated Sensors and Calibration

Using calibrated sensors and creating calibration reports.

Technical Specifications

Measurement Function Specifications

Details accuracy, resolution, and coefficients for measurement functions.

Transmission; Simulation Specs

Summary

Product Introduction

Multifunction Process Calibrator

Overview of the CALYS 50/75/100 multifunction process calibrator.

Software Overview

Safety Instructions

Safety Standards and Operation

Details compliance with EN 61010-1 and safe unit operation guidelines.

Getting Started

Powering On and Basic Measurement

Procedure for initial power-up and basic measurement operations.

Measuring DC Voltage and Current

Step-by-step guides for measuring DC voltage and current.

Temperature and Pressure Measurement

Guides for measuring temperature and pressure.

Generation; Simulation

DC Voltage and Current Generation

Steps to generate DC voltage and current outputs.

Advanced Operation

Simulation Modes Overview

Introduces various transmission modes for checking instruments and transmitters.

Calibrated Sensors and Calibration

Using calibrated sensors and creating calibration reports.

Technical Specifications

Measurement Function Specifications

Details accuracy, resolution, and coefficients for measurement functions.

Transmission; Simulation Specs

AOIP CALYS 100 Specifications

General IconGeneral
DC Voltage Range0 to 1000 V
Thermocouple TypesJ, K, T, E, R, S, B, N
RTD TypesPt100, Pt1000
Power Supply100 to 240 V AC, 50/60 Hz
InterfaceUSB
Operating Temperature-10 °C to 50 °C