Storage of acquisitions in progress D
NTA47230-300A6 79 / 101
PARAMETERS:
Allows you to define:
the size of the acquisition (max 10,000 values),
the sampling period from 0.5 S to 30 Min,
and the type of trigger (None, low level, high level).
If you have selected a low level or high level trigger, you must define the trigger level and the number of data to record
after this trigger (Post-trigger).
Display burst:
You can display the burst in the form of a table of values or a trend curve.
At this level, it is possible to:
- display the trend curve entirely: press the F2 key (GRAPH).
- or place markers so as to display in the form of a graph all the values included between these 2 markers. To do so, press
the F2 key (…).
Post trigger = 900 measurements
Size of block (1,000 measurements)
Trigger on programmed
value = 10°C