  • C
    Charles GillespieAug 9, 2025
    What to do if the AOTAI ATIG315P circuit breaker keeps tripping?
    • C
      clarkmitchellAug 9, 2025
      If the circuit breaker trips automatically (except when working for a long time at high welding current), the IGBT module, three-phase rectifier, or output diode module may be damaged, or there could be a short circuit. Check and replace any damaged components.
  • F
    Francisco NewmanAug 14, 2025
    How to fix AOTAI ATIG315P Welding System over-heat protection?
    • R
      Renee TaylorAug 15, 2025
      If the AOTAI Welding System is overheating, it could be due to the machine being too hot, a faulty temperature relay, or a damaged main control board. Shut down the welding machine and wait for it to cool down. If the problem persists, consider replacing the temperature relay.
  • M
    Maria ArmstrongAug 19, 2025
    Why is the welding current not stable on my AOTAI ATIG315P Welding System?
    • G
      Gabrielle MillerAug 19, 2025
      Unstable welding current in your AOTAI Welding System can be caused by a default phase in the power supply or a damaged main control board. Check the power supply and, if necessary, check and replace the main control board.
  • E
    Erica HansenAug 25, 2025
    How to troubleshoot if the AOTAI ATIG315P doesn't turn on?
    • A
      Allison WilliamsAug 26, 2025
      If the indicator light doesn't turn on and the AOTAI welding machine doesn’t work when switched on, it could be due to a default phase, a broken 2A fuse, or a wire disconnection. * Check the power source. * Check whether the fan, power transformer, and control board are in good condition. * Check and repair any wire disconnections.
  • S
    sullivanaprilAug 29, 2025
    What to do if the welding current is not adjustable on AOTAI Welding System?
    • J
      John ParkerAug 29, 2025
      If the welding current on your AOTAI Welding System is not adjustable, it could be due to a broken inner line or a damaged main control board. Check and replace any broken inner lines.
  • K
    Kathleen MillerSep 3, 2025
    What causes abnormal water-cooling in AOTAI ATIG315P Welding System?
    • N
      Nicholas BaileySep 3, 2025
      Abnormal water-cooling in the AOTAI Welding System can be caused by no circulating water in the water cooling system or a damaged water flow sensor. Check and repair the water cooling system.

Summary

Safety Rules

Electric Shock Can Kill

Details the dangers of electric shock and necessary precautions during welding.

Arc Rays Can Burn

Warns about the dangers of arc rays to eyes and skin and protective measures.

Fumes and Gases Can Be Dangerous

Explains health risks from welding fumes and gases and ventilation requirements.

Welding and Cutting Sparks Hazards

Highlights fire and explosion risks from sparks and necessary precautions.

Cylinder Explosion Risk

Details the dangers of damaged gas cylinders and safe handling procedures.

Hot Parts Burn Hazard

Warns about touching hot components and necessary cooling or protective measures.

Flying Metal or Dirt Eye Injury

Covers risks from flying debris during welding and required eye protection.

Noise Induced Hearing Damage

Addresses hearing damage from noise and the need for ear protection.

Moving Parts Injury Risk

Warns about hazards from moving machine parts like fans and pinch points.

Overuse Caused Overheating

Explains risks of machine overheating due to overuse and how to prevent it.

General Remarks

Before Commissioning

Machine Installation Rules

Provides guidelines for safe and proper installation, including placement and ventilation.

Power Source Connection

Details requirements for connecting the power source, including mains cables and voltage standards.

ATIG315;400;500 P;P-C

Control Panel Overview

Explains the function of each button and indicator on the welding machine's control panel.

Other Functions

Installation

Power Supply and Cable Requirements

Details the necessary power supply voltage, frequency, and cable specifications.

Technical Data

Trouble Shooting

Machine Problems, Causes, and Remedies

Provides a table of common machine faults, their potential causes, and suggested remedies.

Care and Maintenance

AOTAI ATIG315P Specifications