66
TC5-1N5FAB rev.06
TC5-1N5FAB
POSITION DISPLAY MEANING
STAGE 2 / 3
St.2 / Str Stage 2 differential (start temperature)
St.3 / Oft Stage 3 offset
St.3 / Str Stage 3 differential (start temperature)
CURTAINS - DEAD
BAND / TIMER
Deb Curtain Dead Band
ON Time on
OFF Time off
Aut /
Off /
OPE /
CLO
Aut - automatic mode
Off - manual off
OPE - manual open
CLO - manual close
CURTAINS -
MANUAL
Aut /
Off /
OPE /
CLO
Aut - automatic mode
Off - manual off
OPE - manual open
CLO - manual close
MIST
TIMER/
OFFSET/
DIFF.
Oft / StP Mist offset (stop temperature).
diF / Str Mist differential (start temperature).
On Time on for mist cycle.
Off Time off for mist cycle.
StP rH Humidity turn off level.
7
TC5-1N5FAB rev.06
TC5-1N5FAB
LED MEANING
STAGE 1
TURNS ON WHEN STAGE 1 FANS ARE ON.
STAGE 2 / 3
FLASHES WHEN STAGE 2 FANS ARE ON. TURNS ON WHEN STAGE
3 FANS ARE ALSO ON.
CURTAINS
FLASHES WHEN CURTAINS ARE CLOSING. TURNS ON WHEN
CURTAINS ARE OPENING.
MIST
TURNS ON WHEN MIST UNITS ARE ON.
HEATER 1
TURNS ON WHEN HEATER 1 IS ON.
HEATER 2
TURNS ON WHEN HEATER 2 IS ON.
DEF. PROBE/
ALARM
TURNS ON WHEN AN ALARM IS DETECTED. BLINKS WHEN A
DEFECTIVE PROBE IS DETECTED.
COMPENSATION
TURNS ON WHEN THE COMPENSATION ON STAGE 1 MINIMUM
VENTILATION SPEED IS IN EFFECT OR WHEN THE COMPENSATION
ON THE MIST STAGE IS IN EFFECT.
CONTROLLER STATUS LEDS
# OFF ON
1 UNLOCKED PARAMETERS LOCKED PARAMETERS
2 FAHRENHEIT DEGREES CELSIUS DEGREES
3 PROBE 2 DISABLED PROBE 2 ENABLED
4 PROBE 3 DISABLED PROBE 3 ENABLED
5 PROBE 4 DISABLED PROBE 4 ENABLED
6 OUTSIDE PROBE DISABLED OUTSIDE PROBE ENABLED
7 STAGE 3 COOLING STAGE 3 HEATING
8 CASCADING HEATERS ZONED HEATERS
9 NO ACTION
CLOSE PF-5B AIR INLET ON
CURTAIN OPENING
10
FLOATING STAGE 3
DISABLED
FLOATING STAGE 3
ENABLED
11 RESERVED
12 RESERVED
INTERNAL SWITCHES
The internal switches are located on the inside of the front cover. When the
controller is shipped from the factory, all the switches are set to OFF.
ON
2
1
3
4 6 75
8 9
11
10
12