  • L
    Lee SanchezAug 9, 2025
    What to do if the AP&T AP-AB1208 high voltage alarm is on?
    • D
      Daniel HillAug 9, 2025
      If the panel indicator red light is on, indicating a high voltage alarm in your AP&T Power Supply, it could be due to electromagnetic interference. Try turning off the power switch or unplugging the power cable and then restarting the ion bar. It could also be due to abnormal discharge, so confirm the installation location and ensure it is away from surrounding conductors. If these steps don't resolve the issue, the high voltage module may have no power supply or is damaged, requiring you to return it to the factory for maintenance.
  • S
    Stephen LongAug 14, 2025
    Why has the electrostatic removal performance of my AP&T AP-AB1208 decreased?
    • D
      Donald RossAug 14, 2025
      A decrease in electrostatic removal performance of your AP&T Power Supply could be due to several reasons. The discharge needle may be polluted or damaged, in which case you should clean or replace it. Also, check if the discharge seat is tightened properly. Finally, confirm that the ion bar positioning is correct for optimal performance.
  • J
    Joseph MarquezAug 29, 2025
    Why is my AP&T AP-AB1208 Power Supply smoky or burnt?
    • K
      Kathy BurtonAug 29, 2025
      If your AP&T Power Supply is smoky or burnt, it is likely due to a damaged high voltage module or damaged insulation of the discharge seat, requiring you to return it to the factory for maintenance.
  • A
    Angela RyanSep 3, 2025
    What causes decreased electrostatic removal performance in AP&T AP-AB1208 Power Supply?
    • F
      fjacksonSep 3, 2025
      A decrease in electrostatic removal performance in your AP&T Power Supply can occur if there are conductors or another ion bar nearby. Remove any conductors or other ion bars from the vicinity.
  • K
    Kari DixonSep 10, 2025
    How to fix an AP&T AP-AB1208 Power Supply that is unable to discharge?
    • S
      Stephen MonroeSep 12, 2025
      If your AP&T Power Supply is unable to discharge, this may be due to a damaged high voltage module or main-board chip, which requires returning it to the factory for maintenance. Also, a damaged main-board chip can be caused by poor or no grounding. Check the grounding of the ion bar and plant equipment, and return to the factory for maintenance.
  • K
    Kelly RogersNov 23, 2025
    What to do if the RJ45 power port indicator on my AP&T AP-AB1208 Power Supply is off?
    • B
      Brandon HodgeNov 23, 2025
      If the RJ45 power port indicator on the front panel of your AP&T Power Supply is off, it could be due to poor contact of the power cable. Check whether the power cable is in good condition and securely connected. Another cause could be a power supply mismatch; confirm the power supply specification is INPUT 100—240VAC 50/60Hz and OUTPUT 24VDC 2000mA. If there is no power supply and the left port green power indicator is off, check the power supply line. If there is no communication connection or communication failure, and the orange communication connection indicator on the left port is off, check the communication connection and software setup. If only the green light is on at the right port (positive high voltage only), unplug the power cord and restart the ion bar, or reset the working ...

AP&T AP-AB1208 Specifications

General IconGeneral
Input Voltage100-240VAC
Output Voltage12VDC
Output Current8A
Output Power96W
Protection FeaturesOver Voltage Protection, Short Circuit Protection