A2. Check that there is no solution bubbling or leaking around the cup.
A3. Check to make sure the cup gasket is not damaged or missing from the cup lid.
A4. Check to make sure there is no dried solution in the end of the fluid nozzle. Turn T100 Turbo unit
OFF. Remove air cap ring. Remove air cap. Remove Air Distributor Plate. Remove Solution nozzle
(#3) with an adjustable wrench or spanner. There is a Solution nozzle gasket (#4) on the Solution
nozzle. Do not lose it. Rinse Solution nozzle under running water and check for dried solution that
may have blocked the hole. Reinstall Solution nozzle gasket. Reinstall Solution nozzle, Air
distributor plate, Air cap and Air cap ring. Try spraying again. If you still have a problem call for
technical support.
Q4. Solution leaks from in front of the trigger.
A1. Check the solution packing nut for correct tension on the needle. With an adjustable wrench/spanner
tighten Needle packing screw (#7). Do not over tighten. This can cause Solution needle to stick and not
spring back. Try spraying again. If leaking continues the Needle packing needs to be replaced. (Rare).
Remove Solution needle packing screw (#7). Pry out the Solution needle packing (4). Replace.
Reinstall Needle packing nut. Tighten all the way, and then back off slightly. (1/8 turn) Test spray gun for
leakage. If you still have a problem call for technical support.
Q5. When T100 Turbo unit is ON, Solution continues to spray from Spray Gun without trigger being pulled.
A1. Check Needle packing nut tension (#7).
Immediately turn T100 Turbo unit OFF. Disconnect spray gun from air hose. Slightly adjust (loosen)
Needle packing nut (#7). Test to see if problem is resolved.
A2. Check to see that Needle spring is installed (#9). Remove Solution flow screw (#10). Look for
Needle spring around the back of the Solution needle. (See diagram). If lost, call for replacement.
A3. Check Solution nozzle. Remove and clean as needed.
Q6. Solution leaks around the top of the cup.
A1. Make sure the cup is screwed firmly to the body of the Spray Gun.
A2. Make sure the threads around the cup are clean and the threads inside the cup top assembly are
clean.
A3. Replace the cup top gasket. Pry out old gasket. Install new gasket. Test spray gun.