MEAS:ENER:REAC:CHAN? {<channel (0|1|2)>}
Request for reactive energy values in vars in particular channel. Parameter channel can be 0=L1, 1=L2,
2=L3.
MEAS:ENER:REAC:CHAN:PRIM? {<channel (0|1|2)>}
Request for primary reactive energy values in vars in particular channel. Parameter channel can be
0=L1, 1=L2, 2=L3.
MEAS:ENER:REAC:CHAN:K? {<channel (0|1|2)>}
Request for reactive energy values in kvarh in particular channel. Parameter channel can be 0=L1,
1=L2, 2=L3.
MEAS:ENER:REAC:CHAN:PRIM:K? {<channel (0|1|2)>}
Request for primary reactive energy values in kvarh in particular channel. Parameter channel can be
0=L1, 1=L2, 2=L3.
MEAS:ENER:APP?
Request for apparent energy values in VAs.
MEAS:ENER:APP:PRIM?
Request for primary apparent energy values in VAs.
MEAS:ENER:APP:K?
Request for apparent energy values in kVAh.
MEAS:ENER:APP:PRIM:K?
Request for primary apparent energy values in kVAh.
MEAS:ENER:APP:CHAN? {<channel (0|1|2)>}
Request for apparent energy values in VAs in particular channel. Parameter channel can be 0=L1,
1=L2, 2=L3.
MEAS:ENER:APP:CHAN:PRIM? {<channel (0|1|2)>}
Request for primary apparent energy values in VAs in particular channel. Parameter channel can be
0=L1, 1=L2, 2=L3.
MEAS:ENER:APP:CHAN:K? {<channel (0|1|2)>}
Request for apparent energy values in kVAh in particular channel. Parameter channel can be 0=L1,
1=L2, 2=L3.
MEAS:ENER:APP:CHAN:PRIM:K? {<channel (0|1|2)>}
Request for primary apparent energy values in kVAh in particular channel. Parameter channel can be
0=L1, 1=L2, 2=L3.
MEAS:SIGN? {<phase (0|1|2)>},{<unit (0|1)>} ,{<harmonic (0-31)>}
Request for signal’s harmonic content.
Parameters: phase (0=L1, 1=L2, 2=L3), unit (0=U, 1=I) and harmonic number.
Answer: amplitude and phase (two comma separated real numbers).
Examples:
MEASure:SIGNal? 0,0,2 … reading of content of 2
nd
harmonic of U
L1
MEASure:SIGNal? 2,1,5 … reading of content of 5
th
harmonic of I
L3
1.234567E-01, 9.456789E+01 … answer for MEASure:SIGNal? Command
MEAS:SIGN:SAMP? {<phase (0|1|2)>},{< unit (0|1)>}

Other manuals for Applied Precision WS 2320

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Applied Precision WS 2320 and is the answer not in the manual?

Applied Precision WS 2320 Specifications

General IconGeneral
BrandApplied Precision
ModelWS 2320
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals