Notices
ALD-40 CARBON DIOXIDE GAS
LEAK DETECTOR
- Do not submerge the product in water or allow water to enter the
intake of the probe.
- Do not expose the product to temperatures exceeding 60°C.
- Do not leave the product in direct sunlight for long periods of time.
- Do not dismantle or attempt repairs of the product without authorisation.
- Do not change or replace the included lithium battery.
- Do not leave for more than 6 months without charging the battery to
prevent damage.
- Do not use on objects with a charge or appliances connected to a
power source.
- Ensure the filter is present and clean before performing a test.
- Ensure there is enough power before performing a test.
- Use only the supplied charging cable.
- Avoid the inhalation of refrigerant vapor. High concentrations are
harmful and may lead to coma or death.
-ln case of any technical problems please contact us.
sales@aprvtiotech.comhttps://aprvtiotech.com/ +1 713 701 1986 sales@aprvtiotech.comhttps://aprvtiotech.com/ +1 713 701 1986
Technical Specifications Video Instruction
GAS/RSET
H
2
CO
2
HC R1234YF
PEAK
SEN: L
WARM UP
PEAK
MUTESENS
ON/OFF
Question and Answer IconNeed help?

Do you have a question about the APRVTIO ALD-40 and is the answer not in the manual?

Summary

Safety Notices

General Safety Precautions

Key safety guidelines for product usage, including avoiding water, extreme temperatures, direct sunlight, unauthorized repairs, and proper battery handling.

Product Overview and Operation

Product Structure

Details the components of the ALD-40 leak detector, including probe, case, USB port, buzzer, battery, and display indicators.

Key Operation Instructions

Explains the functions of the ON/OFF, RSET, PEAK, SENS, and MUTE buttons for device control and data logging.

Setup and Testing Procedure

Guides users on checking battery levels and performing initial setup before testing for leaks.

Technical Specifications

Device Specifications

Lists technical details: sensor principle, lifespan, sensitivity, alarm modes, battery, working time, charging, environment, storage, weight, size, and certification.

Overview

The ALD-40 Carbon Dioxide Gas Leak Detector is a hand-held device utilizing the infrared spectrum absorption principle for detecting CO2 gas leaks. Compared to traditional leak detectors, it offers a longer sensor life, higher detection accuracy, and a wider range of carbon dioxide detection. The device is equipped with a large LCD screen for intuitive display of test results and features an ergonomic design for user comfort.

Function Description:

The ALD-40 detects carbon dioxide gas leaks by slowly moving its probe (approximately 3 inches per second) at a distance of 0.25 inches near a suspected leak area. When a leak is detected, the screen displays the intensity of the leak, and an audible tone changes to a siren sound. The device is designed to be user-friendly with clear operational controls.

Important Technical Specifications:

  • Sensor Principle: Infrared spectrum absorption
  • Sensor Life: 10 years
  • Sensitivity: 400ppm (ranging from 400ppm to 4000ppm) /year
  • Alarm Mode: Sound and light alarm, LCD display
  • Battery: Built-in rechargeable lithium battery 3.7V 3000mAh
  • Working Time: Continuous 6 hours
  • Charging Time: 4 hours
  • Operating Environment: -10°C to 52°C (14°F to 125.6°F) / Relative humidity (20% to 85% RH)
  • Storage Temperature: -20°C to 60°C (-4°F to 140°F)
  • Weight: 415g (14.6oz)
  • Size: 201mm x 86mm x 38mm (7.9" x 3.3" x 1.5")
  • Certification: CE certification

Usage Features:

The ALD-40 offers several key operational features for ease of use:

  • ON/OFF Key: Press the button for 2 seconds to power the device on or off.
  • RSET Key: Long press the button for 3 seconds to reset the sensitivity benchmark. This is useful for establishing a new baseline for detection.
  • PEAK Key: Press the button to record the maximum value of leakage detected during a test.
  • SENS Key: Press the button to adjust sensitivity levels. The default sensitivity is set to medium.
  • MUTE Key: Press the button to turn the buzzer sound on or off.
  • Setup: Before testing, ensure the device has sufficient battery level. Turn on the device using the ON/OFF button and wait for 30 seconds for it to warm up and stabilize. The sensitivity can be adjusted using the SENS button.

Maintenance Features:

To ensure the longevity and proper functioning of the ALD-40, several maintenance guidelines should be followed:

  • Environmental Protection: Do not submerge the product in water or allow water to enter the intake of the probe. Avoid exposing the product to temperatures exceeding 60°C (140°F) or leaving it in direct sunlight for long periods.
  • Device Integrity: Do not dismantle or attempt repairs without authorization. The included lithium battery should not be changed or replaced.
  • Battery Care: Do not leave the device uncharged for more than 6 months to prevent battery damage. Use only the supplied charging cable.
  • Operational Safety: Do not use the device on objects with an electrical charge or appliances connected to a power source. Ensure the filter is present and clean before performing a test.
  • Health and Safety: Avoid inhaling refrigerant vapor, as high concentrations are harmful and can lead to coma or death.
  • Technical Support: In case of any technical problems, users are advised to contact the provided support channels.