11
SYSTEM OPERATING SPECIFICATIONS
50°F air 63% RH 80°F Water
Model
Discharge Pressure
(psi) Suction Pressure (psi)
Superheat (°F)
ACT-750T4S 335 -345 90 - 95 6 - 10
ACT-1100T5S 325 - 335 90 - 95 6 - 10
ACT-1250T6S 310 - 320 90 - 100 2 - 5
ACT-1500T7S 310 - 320 90 - 100 2 - 5
ACT-1750T7S 310 - 320 90 - 100 2 - 5
ACT-
1250HCT6S 350 - 360 90 – 100 2 - 5
80°F air 63% RH 80°F Water
Model
Discharge Pressure
(psi) Suction Pressure (psi)
Superheat (°F)
ACT-750T4S 340 - 350 150 - 160 8 - 12
ACT-1100T5S 330 - 340 150 - 160 8 - 12
ACT-1250T6S 315 - 325 140 - 150 12 - 16
ACT-1500T7S 315 - 325 140 - 150 12 - 16
ACT-1750T7S 315 - 325 140 - 150 12 - 16
ACT-
1250HCT6S 360 - 370 150 - 160 12 - 16
80°F air 80% RH 80°F Water
Model
Discharge Pressure
(psi) Suction Pressure (psi)
Superheat (°F)
ACT-750T4S 345 - 355 160 - 170 11 - 15
ACT-1100T5S 335 - 345 160 - 170 11 - 15
ACT-1250T6S 320 - 330 140 - 150 18 - 22
ACT-1500T7S 320 - 330 140 - 150 18 - 22
ACT-1750T7S 320 - 330 140 - 150 18 - 22
ACT-
1250HCT6S 370 - 380 150 - 160 18 - 22