Introduction to the Aqua-Hot Hydronic System

System Value and Owner Benefits

Highlights comfort, low emissions, and increased RV value.

Important Notes and Warnings

Stresses reading the guide, qualified service, and potential hazards.

Aqua-Hot System Comfort Features

Comfort Zone 1: Cabin Heat

Provides custom, quiet, and consistent interior heating.

Comfort Zone 2: Continuous Hot Water

Offers on-demand hot water for showers and laundry without recovery time.

Comfort Zone 3: Low Emissions

Emits low levels of fumeless and odorless exhaust, good for environment.

Comfort Zone 4: Service Network

Access to over 160 factory-trained service centers for support.

Comfort Zone 5: Added RV Value

Increases RV resale value, recognized by NADA Guide.

Comfort Zone 6: Low Fuel Costs

Efficiently uses shore power or diesel, reducing propane consumption.

Safety Symbols and Hazard Definitions

NOTICE Symbol Meaning

Alerts to potential equipment damage if instructions aren't followed.

CAUTION Symbol Meaning

Warns of potential minor/moderate injury if instructions are not followed.

WARNING Symbol Meaning

Indicates hazardous situations leading to serious injury or death if not followed.

DANGER Symbol Meaning

Signals immediate risk of serious injury or death if instructions are disregarded.

General Safety Instructions and Precautions

Appliance Usage and Service Precautions

Read guide, learn controls, use qualified technicians, ensure cover is on.

Fluid and Coolant Safety

Use FDA-approved propylene glycol antifreeze for heating and winterizing.

Operational Safety Warnings

Avoid hot exhaust in dry areas, disconnect power before servicing, switch off when refueling.

Aqua-Hot 400-D System Features

System Components and Functions

Describes three systems: interior heat, bay heat, and tank-less hot water.

Power Source Technology

Details TribridHot technology using 120V AC electric and diesel burner.

Product Specifications and Label

Highlights key specs and information found on the product label.

System Component Identification

Cut-Away Diagrams and Part Labels

Visual guide to identify major system components and their locations.

System Controls and Interior Heating Operation

Switches and Thermostat Operation

Explains control switches for burner/electric element and thermostat functions.

Heating Operation Modes

Covers diesel burner and electric element usage for heating.

Controlling Heat Levels and Zones

Details how to set interior thermostat and balance heating zones.

Hot Water System Operation

On-Demand Hot Water Function

Describes how the system provides continuous hot water as needed.

Switch Panel Operation

Guides on locating and operating interior switch panels for system activation.

Aqua-Hot System Operational Flowchart

Routine System Maintenance

Monthly Maintenance Checks

Focuses on checking antifreeze/water solution level in the expansion tank.

Annual Diesel Burner Tune-Up

Recommends annual replacement of fuel nozzle and filter for optimal performance.

Winterization Procedure

Outlines steps to drain the system and add RV antifreeze to prevent freezing.

System Fluids and Water Care

De-Winterization Process

Steps to safely remove winterizing antifreeze and flush the system.

Water System Disinfection

Guidelines for disinfecting potable water systems, avoiding bleach.

Antifreeze Fluid Types and Usage

Explains correct antifreeze types (propylene glycol) and what to avoid.

Antifreeze Mixture and Performance

Recommended Mixture Ratios

Details optimal ratios of propylene glycol and water for performance and protection.

Freeze, Burst, and Boiling Points

Explains how antifreeze affects freezing, bursting, and boiling points.

Corrosion and Rust Inhibition

Describes the role of inhibitors in protecting internal system components.

Antifreeze Testing with Refractometer

Refractometer Operation Guide

Step-by-step instructions for using a refractometer to test antifreeze concentration.

Troubleshooting: Initial Checks and Controller Faults

General System Operation Checks

Basic checks for access cover, fuel level, and solution level before troubleshooting.

Electronic Controller Fault Indicators

Explains RED indicator lights for low tank level, low battery voltage, and overload faults.

Troubleshooting: Indicator Lights and Tempering Valve

Status Indicator Light Meanings

Describes GREEN/RED status lights for heating zones, pumps, and electric element.

Tempering Valve Function and Settings

Explains the tempering valve's role in mixing water and how to check its factory setting.

Aqua-Hot Limited Warranty

Warranty Coverage and Duration

Details the 2-year limited warranty for parts and labor.

Obtaining Warranty Service

Provides contact information for warranty repair authorization and support.